962p_wt1. WATER PIPELINE AND APPURTENANT CONSTRUCTION SHALL BE IN ACCORDANCE WITH EMWD STANDARDS AND SPECIFICATIONS. 2. PRIOR TO CONSTRUCTION OF PIPELINE, CONTRACTOR SHALL EXPOSE EXISTING WATER SYSTEM AND VERIFY ITS EXISTING ELEVATION AND LOCATION. 3. ALL SERVICE CONNECTIONS SHALL BE 1" SERVICES X 1" METERS, UNLESS OTHERWISE NOTED; AND SHALL BE LOCATED AS SHOWN ON THE PLANS AND ADJUSTED AS NECESSARY TO MISS DRIVEWAYS. WATER SERVICE ASSEMBLIES SHALL BE INSTALLED IN ACCORDANCE WITH STD. DWG. B -590A, B -591, TYPE "B". ADJOINING LOT METER BOXES SHALL BE PLACED TOGETHER AT PROPERTY LINES. 4. AIR VALVE ASSEMBLIES SHALL BE INSTALLED IN ACCORDANCE WITH STD. DWG. B -598, TYPE "B". 5. WATER SYSTEM PROFILE ELEVATIONS ARE TO CENTERLINE (CENTER GRADE) OF PIPE. 6. INSTALL LOCATOR WIRE OVER WATER MAIN PER STD. DWG. B -656. 7. FIRE HYDRANT ASSEMBLIES SHALL BE INSTALLED IN ACCORDANCE WITH STD. DWGS. B -362, PAINTED WITH GREEN TOPS AND NOZZLE CAPS, WITH CHROME YELLOW BARREL, CLASS A RATED 1000 GPM AT 20 PSI STANDARD 6 "x4 "x2 -1/2" WET BARREL. HYDRANT MARKERS PER DETAIL SHEET 2. 9. APPROVED RWQCTION PRESSURE %kCKFFLOLd PREVEUT16N DEVIC (R9g7A) (9 - 9876) 4 (13-597c) REQUIRED FOP ALL IAIDUSTRIA) COMMEROM Ap1lQT1MEAITCONYIEXES RtUD LAAIDSCAPE CERVICES', TEMPORARY BLOW -OFF ASSEMBLY SHALL BE INSTALLED IN ACCORDANCE WITH STD. DWG. B -568. IO.ALL P.V.C. PIPE THROUGH 12 INCH SHALL BE TYPE C -900, DR -18, EXCEPT WHERE NOTED OTHERWISE. PIPE SHALL CONFORM TO AWWA SPECIFICATIONS. 11.. FITTINGS FOR P.V.C. PIPE SHALL BE DUCTILE OR GRAY IRON. FITTINGS SHALL BE FLANGED, BOLTED MECHANICAL JOINTS, OR PUSH -ON JOINTS, AND SHALL BE CEMENT MORTAR LINED AND TAR (SEAL) COATED PER EMWD STANDARDS AND SPECIFICATIONS. 12. ALL DUCTILE OR GRAY IRON FITTINGS SHALL BE POLYETHYLENE ENCASED AT THE TIME OF INSTALLATION PER EMWD STANDARDS AND SPECIFICATIONS. 13. A JOINT RESTRAINT DEVICE SHALL BE USED ON ALL MAIN LINE PIPE JOINTS WITHIN SPECIFIED LIMITS AND ALL JOINTS OF WATER APPURTENANCE LATERALS OFF MAIN LINE, PER EMWD STD. DWG. B -663. 14. PRESSURE REGULATING VALVES ARE REQUIRED ON EVERY LOT. EMWD SEWER NOTES 1. SEWER SYSTEM CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH EMWD'S STANDARDS AND SPECIFICATIONS. 2. GRAVITY SEWER PROFILE ELEVATIONS ARE TO FLOW LINE (CONDUIT INVERT). 3. CONTRACTOR HAS THE OPTION TO INSTALL PLASTIC OR VCP SEWERS EXCEPT WHERE SPECIFICALLY DESIGNATED ON PLANS PER EMWD STANDARDS AND SPECIFICATIONS. 4. MANHOLES SHALL BE CONSTRUCTED IN ACCORDANCE WITH STANDARD DRAWINGS SB -53 AND SB -61, AS APPLICABLE. SEWER MAINS MAY BE LAID THROUGH THE MANHOLES AND USED AS A FORM FOR THE INVERT. 5. ALL LATERALS SHALL HAVE AN ON -SITE CLEANOUT IN ACCORDANCE WITH STANDARD DRAWING SB -52. 6. PRIOR TO CONSTRUCTION OF SEWER, CONTRACTOR SHALL EXPOSE EXISTING SEWER AND VERIFY ITS EXISTING ELEVATION AND LOCATION. WHERE CONNECTING TO EXISTING MANHOLES AND INLET STUB OF PROPER SIZE EXISTS, NO ALTERATIONS SHALL BE MADE TO EXISTING MANHOLE BASE OR STUB EXCEPT AS SPECIFICALLY AUTHORIZED BY EMWD. 7. ALL SEWER INLETS AT THE MANHOLE SHALL BE SUCH THAT ITS CROWN SHALL BE LEVEL WITH THE CROWN OF THE OUTLET PIPE, AT THEIR PROJECTIONS TO THE MANHOLE CENTERLINE. 8. RECONSTRUCTION OF EXISTING MANHOLES SHALL BE SCHEDULED AT THE CONVENIENCE OF EMWD AND SHALL BE COMPLETED WITHIN FIVE WORKING DAYS FOLLOWING ITS COMMENCEMENT. r T 9. SEWER LATERALS SHALL BE CONSTRUCTED IN ACCORDANCE WITH SB -177. LOCATIONS OF WYES AND LATERALS, WHERE NOT SHOWN ON THE PLANS; ARE TO BE DETERMINED IN THE FIELD PRIOR TO CONSTRUCTION TO MISS DRIVEWAYS. ALL LATERALS ARE TO BE 4" IN DIAMETER UNLESS OTHERWISE SHOWN ON PLANS. 10. THE CONTRACTOR IS ADVISED THAT THE WORK ON THIS PROJECT MAY INVOLVE WORKING IN A CONFINED AIR SPACE. CONTRACTOR SHALL BE RESPONSIBLE FOR "CONFINED AIR SPACE" ARTICLE 108, TITLE 8, CALIFORNIA ADMINISTRATIVE CODE. 11. WHERE GROUNDWATER IS ENCOUNTERED, ALL VCP PIPE SHALL BE TREATED FOR ABSORPTION RESISTANCE PER EMWD'S SPECIFICATIONS. 12. BACKWATER VALVES SHALL BE INSTALLED PER SECTION 710.1 OF THE UNIFORM PLUMBING CODE. 13. ALL PIPE ZONE BEDDING AND TRENCH BACKFILL ARE TO BE PER STANDARD DRAWING SB -157, SB -158 AND SB -159. I CERTIFY THAT THE DESIGN OF THE WATER SYSTEM IN TRACT NO. 36418 IS IN ACCORDANCE WITH THE REQUIREMENTS PRESCRIBED BY THE RIVERSIDE COUNTY FIRE DEPARTMENT. JENS THIELMANN DATE WATER CERTIFICATION a I CERTIFY THAT THE DESIGN OF THE WATER SYSTEM IN TRACT NO. 36418 IS IN ACCORDANCE WITH THE WATER SYSTEM EXPANSION PLANS OF THE EASTERN MUNICIPAL WATER DISTRICT, AND THAT THE WATER SERVICE, STORAGE AND DISTRIBUTION SYSTEM WILL BE ADEQUATE TO PROVIDE WATER TO SUCH TRACT. THIS CERTIFICATION DOES NOT CONSTITUTE A GUARANTEE THAT IT WILL SUPPLY WATER TO SUCH TRACT AT ANY SPECIFIC QUANTITIES, FLOWS OR PRESSURES FOR FIRE PROTECTION OR ANY OTHER PURPOSE. :4 2 E 1 110112.3 _ l' "_19OR 1 DY: 11 13 CIVIL ENGINEER OF SUBDIVISI S DATE SHEET INDEX 1 TITLE SHEET 2 INDEX SHEET 3 ARROWLEAF LANE 10 +00 TO 18 +45.82 4 JASMINE LANE 10 +00 TO 18 +93.22 1 Iltt!I h w I.riuI� ri irrr 11 'r � 1l I� zttu !, i9!! �' JA 4 AM,] 4 \• i AT LEAST 48 HOURS PRIOR TO COMMENCING CONSTRUCTION, CONTRACTOR SHALL NOTIFY: EASTERN MUNICIPAL WATER DISTRICT - FIELD ENG. DEPT. (951) 928 -3777 EXT. 4830 UNDERGROUND SERVICE ALERT (USA) 1 (800) 227 -2600 OR 811 RIVERSIDE COUNTY TRANSPORTATION DEPARTMENT 951 -955 -6885. ALL OTHER AGENCIES THAT ARE NOT MEMBERS OF USA. Ik o THE EXISTENCE AND LOCATIONS OF ALL UNDERGROUND UTILITIES SHOWN (MAIN UNES -NO LATERALS OR SERVICES SHOWN) ON THE DRAWINGS WERE OBTAINED FROM AVAILABLE RECORDS AND ARE APPROXIMATE. NEITHER THE OWNER NOR THE ENGINEER ASSUMES ANY RESPONSIBIUTY FOR UTILITIES NOT SHOWN OR NOT IN THE LOCATION SHOWN. THE CONTRACTOR SHALL DETERMINE THE DEPTH AND LOCATION OF EXISTING UNDERGROUND UTILITIES PRIOR TO TRENCHING AND SHALL BE REQUIRED TO TAKE PRECAUTIONARY MEASURES TO PROTECT ALL UNES SHOWN AND /OR ANY OTHER UNDERGROUND UTILITIES NOT OF RECORD OR NOT SHOWN ON THE PLANS. CALL UNDERGROUND SERVICE ALERT 1- 800 - 227 -2600 AT LEAST 48 HOURS PRIOR TO EXCAVATION. i ' EL • ■ RIVERSIDE COUNTY B.M. T- 49 -81, 2.5" BRASS DISK IN CONC. CYLINDER LOCATED AS FOLLOWS: FROM THE INT. OF RANCH CA. RD. & FRONT ST. 1.7 MI. NW ON FRONT ST. /JEFFERSON AVE. TO THE INT. OF JEFFERSON & WINCHESTER RD. (HWY 79), 5.5 MILES NE ON WINCH. RD. (HWY 79) TO THE ]NIT, OF WINCH. AND BENTON RD., .05 MI. W. ON BENTON RD TO THE BENTON/BRIGGS ROAD INT., 0.5 MI. N ON BRIGGS RD TO THE BRIGGS /THOMPSON RD INT., 200' E. OF THE INT., 22' S. OF THE CA THOMPSON RD. NEAR THE NW COR OF 16' X 22' CHAIN LINK FENCE AROUNND SOUTHERN CAL. GAS CO. VALVES. WIRED PADDLE MARKED TO FENCE. 1. PERMITS FROM OTHER AGENCIES. APPROVAL BY EMWD IMPLIES NO PERMISSION OTHER THAN THAT WITHIN THE DISTRICT'S JURISDICTION. ALL PERMITS REQUIRED BY LAW SHALL BE ACQUIRED BY THE DEVELOPER OR HIS CONTRACTOR. REQUIREMENTS OF EMWD SHALL TAKE PRECEDENCE OVER REQUIREMENTS OF OTHER AGENCIES ONLY WHERE EMWD REQUIREMENTS ARE GREATER. 2. COORDINATION OF WORK. THE PROPOSED WORK SHALL BE SUBORDINATED TO ANY OPERATIONS EMWD MAY CONDUCT AND SHALL BE COORDINATED WITH SUCH OPERATIONS AS DIRECTED BY EMWD. 3. APPROVAL OF GRADES. APPROVAL BY EMWD OF A PROPOSED CONNECTION TO AN EMWD FACILITY DOES NOT IMPLY APPROVAL OF THE CORRECTNESS OF THE ELEVATIONS SHOWN ON THE PLAN. 4. STANDARDS OF CONSTRUCTION ALL WORK SHALL CONFORM TO THE RECOGNIZED STANDARDS OF CONSTRUCTION AS REQUIRED AND APPROVED BY EMWD. 5. WATERLINE INSTALLATION TO BE MADE FOR EASTERN MUNICIPAL. WATER DISTRICT. 6. ALL MATERIALS TESTING AND INSPECTION OF PIPE SHALL BE IN CONFORMITY WITH THE REQUIREMENTS OF RIVERSIDE COUNTY AND THE AMERICAN WATER WORKS ASSOCIATION (AWWA) STANDARDS. 7. WATER AND SEWER SEPARATION SHALL CONFORM TO THE STATE HEALTH CODE STANDARD. 8. FAILURE TO MEET ANY OF THE REQUIREMENTS OF RIVERSIDE COUNTY AND THE AWWA SPECIFICATIONS WILL BE CAUSE FOR REJECTION. 9. MINIMUM WATER PIPE COVER SHALL BE 48 INCHES. 10. ALL MATERIAL USED AND INSTALLATION SHALL CONFORM TO RIVERSIDE COUNTY SUBDIVISION IMPROVEMENT ORDINANCE NO. 461. 11. LOCATION OF ALL WATER /SEWER FACILITIES ABOVE GROUND SHALL CONFORM TO RIVERSIDE COUNTY ROAD IMPROVEMENT STANDARDS AND SPECIFICATIONS. 12. PLACEMENT OF BLUE REFLECTIVE PAVEMENT MARKERS SHALL BE AS PER RIVERSIDE COUNTY FIRE DEPT- GUIDELINES HANDOUT. TIME LIMITATION THE TIME LIMIT ON DRAWING(S) APPROVAL SHALL BE SIX (6) MONTHS FROM THE DATE ON THE CERTIFICATION. IF CONSTRUCTION HAS NOT COMMENCED WITHIN STATED TIME, EMWD REQUIRES DRAWING(S) TO BE REVIEWED BY THE DEVELOPER /DESIGN ENGINEER AND RESUBMITTED TO EMWD FOR POSSIBLE CHANGES IN MASTER PLANNED SIZING AND CHANGES IN SPECIFICATIONS AND STANDARDS I CERTIFY THAT THE DESIGN OF THE SEWER SYSTEM IN TRACT NO. 36418 IS IN ACCORDANCE WITH THE EASTERN MUNICIPAL WATER DISTRICT'S SEWER SYSTEM MASTER PLAN, AND THE DISTRICT HAS PROGRAMMED ADEQUATE CAPACITY TO TREAT WASTES FROM THE PROPOSED TRACT. BY: ` �. CIVIL ENGINEER OF B r r. PL PL R /W_ _SEWER LATERAL MIN WATER LATERAL H 10' MAX & 5' MIN N.T.S. COUNTY OF RIVERSIDE FIRE DEPARTMENT i I, EXISTING 18" SEWER PER D -34813 PROPOSED 8" WATER PER D- 34813 0 L'O 11 s Li ." CL Li r C EXISTING 1g' SEWER PER D -34813 PROPOSED 8" WATER PER D- 34813 EXISTING 8" SEWER PER D -34813 * 8 b e l ow. re 8 11 C bef 1 PROPOSED 8" WATER PER D -34814 PROPOSED 18" SEWER PER D -34814 , I I ff .I \ ,1-1 I w MA 41 I 40 PR PR 13 P2 11 O O PR PR PR 4 — — ESTIMATE OF QUANTITIES — — - '� oacROSE' � CLINTON KIE(H SI - EXISTING 16" WATER PER WATER — — EXISTING 18" SEWER PER D -34811 8" WATERLINE PVC C -900, DR -18 10 1668 LF 6' ELBOW O 7 EA PR STD F.H. (B -362) 4 EA 1" SERVICE CONNECTIONS W/ 1" METER 50 EA FIRE HYDRANT MARKER 4 EA U w °' 2" SERVICE CONNECTION W/ 1" METER 1 EA 2" SERVICE CONNECTION W/ 1.5" METER L u 1 EA CONSTRUCT PER DETAIL ON THIS INDEX SHEET w w �I U O O PRESSURE REGULATING VALVE 50 EA VE SEWER d VICINI 6' SEWER r = 1736 LF MANHOLES 5 EA SEC 31, US, RA, St's TERMINUS MANHOLES 1 EA 4" SEWER LATERALS 50 EA BACKWATER VALVE: LOTS 1 -4, 9 -13, 18 -22, 26 -28, 31 -33, 39, 43, 48 -50 — 25 EA A PRESSURE REGULATING VALVE SHALL BE INSTALLED ON EVERY LOT. IP130011 PRESSURE ZONE: M.V. ELEV: 1627 WATER /SEWER APPROVED BY: IV�I�SI I.D. U24 & U2 STERN MUNICIPAL WATER DISTRICT w O. 43 13 34E TRACT NO. 36418 c. ®. SEWER AND WATER COORD, 14 —A—: E NGINEER S DATE CIVIL ENGINEER F SUBDIVISIO _ w MA 41 I 40 PR PR 13 P2 11 O O PR PR PR 4 — — — — - '� oacROSE' � CLINTON KIE(H SI - EXISTING 16" WATER PER D -34811 — — EXISTING 18" SEWER PER D -34811 J 10 9 B aw O PR Or PR PR ,, MH1 #5 7 6 5 1 1 2 1 PR PR PR O O PR PR 11 SEWER PR PR MH #4/ - FH (B- 362) 8" WATER �n E ET 3 FH (8 -362) 19 20 u u 21 22 23 24 25 26 27 28 O S O PR PR PR O PR PR PR PR PR PR PR 8" SEWER 38 37 36 35 34 33 32 31 30 29 /J PR PR PR pR PR O PR PR �/ p PR PR PR I( l! Il MH #1 s" SEWER MH #2----, 8" SEWER \/ � FH (B -36 I T WATER 50 PR 51 PR WATER QUALITY BASIN m WATER LEGEND o-- SERVICE CONNECTION WITHOUT METER �- SERVICE CONNECTION WITH METER O 1" AR & AV 4-4 STANDARD F.H. (B -362) JM[ RESILIENT SEAT GATE VALVE FxH RESILIENT SEAT GATE VALVE FxF K FxH ADAPTER RESTRAINED FITTING END ]{ H x H REDUCER - - - WATER LINE EXISTING OR PROPOSED BY OTHERS WATER LINE 6" B.O. (8-568) TEMPORARY D� 6" B.O. (B -357) PERMANENT REDUCED PRESSURE BACKFLOW DEVICE (B -597) SEWER LEGEND SEWER LINE - - - SEWER LINE EXISTING OR PROPOSED BY OTHERS SEWER LINE WITH LATERALS 0 MANHOLE O BACKWATER VALVE PR PRESSURE REGULATING VALVE IMPLEMENTING FACILITIES 8" WATERLINE IN ROCKROSE LN. PER D- 34813. 18" SEWERLINE IN ROCKROSE LN. PER D- 34813. 8" WATERLINE IN PRAIRIE SUN WAY PER D- 34814. 18" SEWERLINE IN PRAIRIE SUN WAY PER D- 34814. 18" SEWERLINE THROUGH TRACT 32289. �j L N c� SCALE 1 " =50' 0' 50' 100' 150' 1 2 3" FAI '� oacROSE' � CLINTON KIE(H SI ,,, o z N — RD �o BELT J P uc U Or o �� ® m J ® H Tt _Z 19 3 Q U w °' L u j w w �I U O O N ui `cW O d VICINI r = z a r _ 3 SEC 31, US, RA, St's N.T.S. m WATER LEGEND o-- SERVICE CONNECTION WITHOUT METER �- SERVICE CONNECTION WITH METER O 1" AR & AV 4-4 STANDARD F.H. (B -362) JM[ RESILIENT SEAT GATE VALVE FxH RESILIENT SEAT GATE VALVE FxF K FxH ADAPTER RESTRAINED FITTING END ]{ H x H REDUCER - - - WATER LINE EXISTING OR PROPOSED BY OTHERS WATER LINE 6" B.O. (8-568) TEMPORARY D� 6" B.O. (B -357) PERMANENT REDUCED PRESSURE BACKFLOW DEVICE (B -597) SEWER LEGEND SEWER LINE - - - SEWER LINE EXISTING OR PROPOSED BY OTHERS SEWER LINE WITH LATERALS 0 MANHOLE O BACKWATER VALVE PR PRESSURE REGULATING VALVE IMPLEMENTING FACILITIES 8" WATERLINE IN ROCKROSE LN. PER D- 34813. 18" SEWERLINE IN ROCKROSE LN. PER D- 34813. 8" WATERLINE IN PRAIRIE SUN WAY PER D- 34814. 18" SEWERLINE IN PRAIRIE SUN WAY PER D- 34814. 18" SEWERLINE THROUGH TRACT 32289. �j L N c� SCALE 1 " =50' 0' 50' 100' 150' 1 2 3" FAI rZaTa m �fiwnm 0 w