Loading...
933v_ls0 0 C J2' PALM TREE PLANTING NOTES 6a PLANTING NOTES Er I. Before any plants are planted, all planted areas are to have been graded in on acceptable manner to asssure positive drainage per the grading notes. 2. Where circumstances permit, plant no tree closer than Ib' to an edge of horoscope. 3. Remove ail stakes from vines 4. Refer to planting details. 5. Whenever possible, use plant materials acclimated to the Coachella Volley. 6- Landscape contractor when tying vines is to use a drill to establish the pilot hole to receive the red -head portion of the molly. 7. When tying vines or espaliers, wires should be spaced as follows: Ist (2) at I' -6" apart from finish grade, the next (3) at I' -O" apart to make the top wire at 6-0" above finish grade. Wires should be a minimum of b' -O" long center on plants. When vines or espaliers are closer than 10' apart, use a continuous wire between both plants. S. WARNIN& Plant material listed may or may not have been approved by the Agricultural Commissioner's office. Landscape contractor, please contact the developer for status of Agricultural Gommissioner's approval or denial. Plant material not conforming with quarantine laws may be destroyed and civil action taken. All plant material is subject to Inspection at the discretion of the Agricultural Commissioner's office. All plant material must be free from Red Scale (Aonidiella ourantii). q. No shrubs are to be planted within Ib" of handscape, measured from center of shrub. M • • M F03 2 N06'34'0' s 2 2 5YMBOL SIZE TONS W QUANTITY E 2'x5'x2' I 14 F 5xl'x2' .5 12 6 2'x2'xl' .25 Ig 4. 6. b. q. lo. II. 12. 13. 14. 15 16 17 IE Palms shall be planted using established planting procedures. Refer to palm tree planting detail. Palm tree root balls shall be trimmed or cut to ensure recovery from transplanting shock. Palm trees must be in a healthy condition at time of delivery. Palm trees determined unhealthy or damaged at time of delivery or installation shall be rejected by contractor and replaced by subcontractor at his expense. All palms shall be cleaned of excessive dead and ragged fronds or frond stubble. Out fronds should be out to a maximum length of 6 ". Galled out heights of palms shall be THE HEIGHT FROM TOP OF ROOT BALL TO BOTTOM OF L 1 VE FRONDS. Palm trees to be properly watered in and soils properly tamped around the root balls when planting, leaving no voids of soil around root balls. Palm trees shall be planted vertically, unless noted otherwise. Trunks should be rough with frond bases still securely attached. Trunks may not be totally skinned unless noted to do so. Trunk bases may be skinned to a maximum height of 3' -4' (taller trees 69 Skinned areas above the 6 level Y011 be accepted, at the direction of the Landscape Designer. Gore should be exercised in the cabling during transport and planting so as not to damage or loosen bark. Severe cracking or holes in the basal trunk area will not be acceptable. One initial watering will be performed by subcontractor. Basin will be left on each palm so subsequent watering can be performed by others. Basin is to be removed during finish grading. Subcontractor to untie frond tops (60) days after planting. Palm trees shall be planted a minimum of 15" awou from building eaves. It is recommended any palm tree planted within 5 of any walk, wall or structure be planted with Deep Root root barrier to a depth of 2' minimum to protect against root damage. Washingtonia robusta trunks are to have a minimum diameter of 14" measured 4' high on trunk above finish grade. NOTE: NO PALM TREE SHALL BE OUT OF THE ORIGINAL &ROUND FOR MORE THAN (4b) HOURS PRIOR TO RELOCATION AND PLANTING. 0 i I PALM5 5YM. NAME WATER U5 -G_ SIZE QTY. COMMENTS Ghamaerops humilis (M) 15 gal. 13 Multi Ghamaerop5 humlll5 Washingtonia robusta (M) See Plan 2"1 S.T.H. Mexican Fasn Palm 5HRUB5 5YM. N WAT U5AGE SIZE CITY. GOMMENT5 Bougainvillea 'La Jolla' (M) 5 gal "i Low growing r_ Bougainvillea La Jolla O Gari5sa g. 'Boxwood Beauty' (M) 1901. 44 Boxwood Beauty' O Lantana montevidensi5 'Purple' 1 901. 44 purple Purple Spreading Lantana (M) O Muhlenbergia 1901 37 Reagol Mist (M) Pennl5teum setacceum I a 35 Purple Fountain 6ra55 (M) VINE 5Y M. NAME WATER U5A6E 51ZE Q TY. GOMMENT5 Galliandra inequilatera (M) 5 gai. 41 Vine Pink Powder Puff 6 ROUND COVERS 5YM. NAME SIZ QTY. COMMENTS DEGOMP05ED 6RANITE ' MOJAVE GOLD' 2" THIGK IN ALL PLANTERS 3/8 "- FINE5 WETTED @ ROLLED TO 010% GOMPAGTION NOTE: ALL allANTITIE-5 ARE FOR ESTIMATE PURPOSE ONLY. CONTRACTOR TO VERIFY GUATITIES. Ili • • • • ilil - NOTE: Root B Depth MIN. 13 rr DEPTH OF ROOTBALL 0 grade in lawn Undisturbed subgrade 'THE ANNEXATION OF THE EXTERIOR PERIMETER INTO THE HOA'S RESPONSIBILITY FOR MAINTENANCE WAS APROVIDED BY THE LAGUNA SECA HOA MINUTES DATED 2/18/05 FOR PLANT PIT 51ZE REFER TO 5PEOFIGATION5 5EE THI5 5HEET. ®/, • -II I WE UNTANGLE MATTED ROOT5 BY L005ENIN6 ALL ROOTS ® E06E IIIIII OF ROOT BALL w/ WATER FROM H05E. DO NOT GRAGK ROOTBALL. \_PL,W N6 PIT TO BE 3 TIMES THE 512E OF ROOT BALL Ilk DEPRE55ED WATERING BANN TO REMAIN DURING PLANT N.T.S. E5TABL15HMENT PERIOD. BAGKFILL MIX PER 5PEG5. ^✓ 5EE 5PEGIFIGATION5 TH15 5HEET. r— FIN15H GRADE FOR PLANT PIT 51ZE REFER TO 5PEOFIGATION5 5EE THI5 5HEET. ®/, • -II I WE UNTANGLE MATTED ROOT5 BY L005ENIN6 ALL ROOTS ® E06E IIIIII OF ROOT BALL w/ WATER FROM H05E. DO NOT GRAGK ROOTBALL. \_PL,W N6 PIT TO BE 3 TIMES THE 512E OF ROOT BALL Ilk PALM TREE PLANTING SHRUB PLANTING N.T.S. N.T.5. LL V LL VI \/ \LL NOTE: 130ULDER5 IN GLU5TER5 ARE TO BE 5ET AT VARIED HE16W5 BOULDER NOTE: �i / \ F \TqT f CLUB ALL GAVITIE5 AND V0105 Boulders are to be Desert Surface Select which have NO sharp ARE TO BE BURIED edges. If a boulder happens to have sharp edges face them away from the sidewalk. All boulders are to be setback to 2 feet from FIN15H GRADE the edge of sidewalk. ALL CAVITIES AND VOID5 ARE TO BE BURIED C BOULDER PLACEMENT N.T.5. TR. 30866 4b r ALLIGATOR POND ROAD U EWARTON ROAD ¢� SAVANNA LA bfAR DR 42nd �� M AVE. VICINIT 1VIAP NO SCALE THOMAS BROS. COORDINATES PAGE 819, G -4, 2002 EDITION SCHEDULE NOTE: WORK CONTAINED WITHIN THESE SEAL COUNTY OF RIVERSIDE _._. BENCH MARK: TRACT NO. 30866 - I.P. NO. 030131 SHEET NO. PLANS SHALL NOT COMMENCE UNTIL AN ENCROACHMENT PERMIT AND /ORAGRADING Oy ESS/Oy TRANSPORTATION DEPARTMENT - — COUNTY OF RIVERSIDE PERMIT HAS BEEN ISSUED. �~� �0 A. O �' T FG APPROVED BY: ABO� Important Notice - Underground Service Alert ¢ r GM FUTURE DESIGN PLAN L — o SECTION 4216/4217 OF THE GOVERNMENT CODE No. 33950 w PLA N N Landscape Design Services REQUIRES A DIG ALERT IDENTIFICATION NUMBER BE * Exp. 6/30/06 * J Q N KHAL A. 0TH PORTION BEFORE A 'PERMIT TO EXCAVATE' WILL BE VALID RC 3 50 P. 0 -06 DATE 9j �2 81390 Golf View Drive DESIGN BY: GM SCALE: AS NOTED POROM NORM MI/4 AND THE 17 OF 3 SHTS. FOR YOURD D IG ALERT ID ALERT TOON N A800 MARK BY DATE APPR. DATE STgTf OF CP �\P V OF CA��FO La QUinta, California 92253 DRAWN BY: GM PLOT DATE: 11/12/04 SECTION "f, T.5S5, R.?E., 9D.M. 227 -2600 TWO WORKING DAYS BEFORE YOU DIG. E oMMENDE D —�� Phone: (760) 899 -5894 FOR: W.o. coUNTY ARCHITECT REVISIONS COUNTY Fax: (760)564-7535 CHECKED BY: DWG: LAGUNA SECA, LLC 080804 E1LE NO. LE M BOULDER NOTES: Boulders are to be Desert Surface Select varying in size. Boulders are identified on landscape plan by letter, 'E' being the largest and 'G' being the smallest Landscape contractor to vary the sizes and heights when placing boulders in clusters. Boulders to be buried no less than 113 of their height upon final grading. --0V%PftW- r— FINISH GRADE SLOPED GRADE 0 C .Ii i F PIPE SIZING CHART PIPE SIZE MAX. ALLOWABLE FLOW 1/2" 5 GPM 3/4" 10 GPM 1" 16 GPM 1 -1/4" 26 GPM 1 -1/2" 40 GPM 2" 60 GPM L A 1 I =1 m y A l l al _ 1 01 0 J P.O.C. 8/4 Meter and T Backflow PreventoY inetailled per C.V.WD. \ e 1. THE SPRINKLER SYSTEM DESIGN IS BASED ON THE MINIMUM OPERATING PRESSURE AND THE MAXIMUM FLOW DEMAND SHOWN ON THE IRRIGATION DRAWINGS AT THE METER OR POINT OF CONNECTION. THE IRRIGATION CONTRACTOR SHALL VERIFY WATER PRESSURE PRIOR TO CONSTRUCTION. REPORT ANY DIFFERENCE BETWEEN THE WATER PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO THE OWNER'S AUTHORIZED REPRESENTATIVE, IN THE EVENT PRESSURE DIFFERENCES ARE NOT REPORTED PRIOR TO START OF CONSTRUCTION, THE IRRIGATION CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY. 2. 120 VOLT ELECTRICAL POWER OUTLET AT THE AUTOMATIC CONTROLLER LOCATION SHALL BE PROVIDED BY OTHERS. IT SHALL BE THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO MAKE THE FINAL HOOK -UP FROM THE ELECTRICAL OULTLET TO THE AUTOMATIC CONTROLLER. 3, THIS DESIGN IS DIAGRAMMATIC. ALL PIPING, VALVES, ETC. SHOWN WITHIN PAVED AREAS IS FOR DESIGN CLARIFICATION ONLY AND SHALL BE INSTALLED IN PLANTING AREAS. AVOID ANY CONFLICTS BETWEEN THE SPRINKLER SYSTEM, PLANTING AND ARCHITECTURAL FEATURES. 4. THE IRRIGATION CONTRACTOR SHALL FLUSH AND ADJUST ALL SPRINKLER HEADS FOR OPTIMUM PERFORMANCE AND TO ALLOW FOR NO OVERSPRAY ONTO WALKS, ROADWAYS AND /OR BUILDINGS. THIS SHALL INCLUDE SELECTING THE BEST DEGREE OF ARC TO FIT THE EXISTING SITE CONDITIONS AND TO THROTTLE THE FLOW CONTROL AT EACH VALVE TO OBTAIN THE OPTIMUM OPERATING PRESSURE FOR EACH SYSTEM. 10 N06'34'0' r IRRIGATION CONTROLLER DRIP IRRIGATION LEGEND SYMBOL MANUFACTURER MODEL NO. DESCRIPTION NOZZLE RADIUS FLOW PSI PATTERN &PM/GPH ■ RAINBIRD 1401 Detail D' Shoat L -3 trickle bubbler - 25 gpm 25 UMBRELLA • RAINBIFD XBT -10 Detail D' Sheet L -3 drip emitter - 19ph 25 DRIP V RAINBIRD )OT-20 Detail 'D' Sheet L -3 drip emitter - 2 gph 25 DRIP < SYMBOL INDICATES BUBBLER 6ROUPIN6. REFER TO DETAIL ON SHEET. ®A RAINSIRD E5P_1l 6 STATION RESIDENTIAL HYBRID CONTROLLER. Detail 'G' ® RAINBIRD "DV" SERIES REMOTE CONTROL VALVE, SIZE AS NOTED ON PLAN. Detail 'F' ® RAINBIRD "DV" SERIES REMOTE CONTROL DRIP VALVE ASSEMBLY, 51ZE AS NOTED ON PLAN. Detail 'A' XGZ -015 xCZ-100 ►® KBI #mIP- 1000 -T BALL VALVE (LINE 51ZE). Detail '6' ® RAINBIRD 3RC 3/4" QUICK COUPLER. Detail 'B' - - -- PRESSURE MAINLINE PIPING USE SCHEDULE 40 - SIZE AS NOTED NON- PRE55URE LATERAL LINE PIPING - PI GLASS 200 and 315. ® ® P.O.G. (Point of Comection) 3/4" Meter and I" Backflow Preventor Installed per G.VYI PIPE SLEEVIN6 SHALL OCCUR UNDER ALL MAJOR HARDSGAFE. 5LEEVIN6 (5ch. 40) SHALL BE 2X THE DIAMETER OF THE PIPE. INDICATES CONTROLLER NUMBER EZ INDICATES FLOW IN GALLONS PER MINUTE INDICATES ZONE TYPE INDICATES ELECTRIC CONTROL VALVE SIZE DENOTED TREE5 WITHIN 10 FEET OF HARD5GAPE, WALL5 OR 13UILDIN65 TO REGIEVE 'DEEPROOT' ROOT BARRIER5 PER MANUFAGTURER'5 5PEGIFIGATION5 NOTE I. MAINLINE, LATERALS AND VALVES ARE SHOWN OUT5IDE PLANTING AREAS FOR GRAPHIC CLARITY ONLY. THEY SHOULD BE IN5TALLED IN SHRUB AREAS. 2. 51LEEVIN& (5Gh. 40) 5HALL OCCUR UNDER ALL HANDSCAPE SURFACES. 3. BEFORE IN5TALLATION OWNER is TO APPROVE IRRIGATION CONTROLLER LOCATION AND PROVIDE ELEGTRIGAL 5OURCE FOR CONTROLLER. 4. CONTRACTOR TO REPLACE 4 OR REPAIR ALL EXISTING LAND5CAPE AND IRRIGATION DAMAGED DURING CON5TRUCTION. i Ili I II j ( 1 i7AlA'uL: SYM. N WATER U5A6E BUBBLER _.— Ghamaerope humilis (M) 1 (1401) Ghama,I humills Washingtonio robu5ta (M) 2 (1401) Mexican Fasn Palm SHRU65 5YM. NAME WATER USAGE EMITTERS Bougainviilea 'La Jolla' (M) XBT -20 -- Bougainvillea La Jolla f� Larissa g. 'Boxwood Beauty' (M) XBT -20 Boxwood Beauty ® Lantana monteviden515 'Purple' XBT -20 Purple 5preading Lantana (M) O Muhlenbergia XBT -20 Reagol Mist (M) Pennl5teum setocceum XBT -20 Prupie Fountain brass (M) VINES 5YM NAME WATER U5A6E _ 51ZE QTY. G Galliandra inequilatero (M} XBT -2O Pink Powder Puff 10' 10' 10' 10' 111=11 5. DO NOT WILLFULLY INSTALL THE SPRINKLER SYSTEM AS SHOWN ON THE DRAWINGS WHEN IT IS OBVIOUS IN THE FIELD THAT OBSTRUCTIONS, GRADE DIFFERENCES OR DIFFERENCES IN THE AREA DIMENSIONS EXIST THAT MIGHT NOT HAVE BEEN CONSIDERED IN THE ENGINEERING. SUCH OBSTRUCTIONS OR DIFFERENCES SHOULD BE BROUGHT TO THE ATTENTION OF THE OWNER'S AUTHORIZED REPRESENTATIVE. IN THE EVENT THIS NOTIFICIATION IS NOT PERFORMED, THE IRRIGATION CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR ANY REVISIONS NECESSARY. 6. IT IS THE RESPONSIBILITY OF THE IRRIGATION CONTRACTOR TO FAMILIARIZE HIMSELF WITH ALL GRADE DIFFERENCES, LOCATION OF WALLS, RETAINING WALLS, ETC. HE SHALL COORDINATE HIS WORK WITH THE GENERAL CONTRACTOR AND OTHER SUB - CONTRACTORS FOR THE LOCATION AND THE INSTALLATION OF PIPE SLEEVES THROUGH WALLS, UNDER ROADWAYS, PAVING, STRUCTURES, ETC. 7, IN ADDITION TO THE CONTROL WIRE SLEEVES SHOWN ON THE DRAWINGS, THE IRRIGATION CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF 'CONTROL WIRE SLEEVES OF SUFFICIENT SIZE UNDER ALL OTHER PAVED AREAS. 8. CONTRACTOR TO CONTACT CITY LANDSCAPE REPRESENTATIVE FOR TEST OF MAINLINE PRIOR TO BACKFILLING TRENCHES. `THE ANNEXATION OF THE EXTERIOR PERIMETER INTO THE HOA'S RESPONSIBILITY FOR MAINTENANCE WAS APROVIDED BY THE LAGUNA SECA HOA MINUTES DATED 2/18/05 i \ rgTF COUNTRY TR. 30866 SAVANNA LA MAR 42ad I — I AVE NO SCALE THOMAS BROS. COORDINATES PAGE 819, G -4, 2002 EDIDON SCHEDULE "B" r1 I' NOTE: WORK CONTAINED WITHIN THESE SEAL COUNTY OF RIVERSIDE BENCH MARK: SHEET NO. PLANS SHALL NOT COMMENCE UNTIL AN COUNTY TRACT NO. 30866 I.P. NO. 030131 ENCROACHMENT PERMIT AND /ORAGIMDING ESSID TRANSPORTATION DEPARTMENT - PERMIT HAS BEEN ISSUED. � A Fti APPROVED BY: ABO ti - COUNTY OF RIVERSIDE I _ I Notice — Underground Seance Alert YP� GM FUTURE DESIGNS (� I® oRE SECTION 4216/4217 OF THE GOVERNMENT CODE No. 33950 J �z Z7 •0� "' Y`a RI GATI®` • N PL 'N REQUIRES A DIG ALERT IDENTIFICATION NUMBER BE * Exp. 6/30/06 * � � R '' ° U Landscape Design Services ISSUED BEFORE A 'PERMIT TO EXCAVATE' WILL BE VALID HOTHM DATE 81390 Golf View Drive A PORTION OF NORTH NI AND THE 5151/4 OF 3 FOR YUR DIG ALERT 9 DESIGN BY: GM SCALE: AS NOTED OF SHTS. UNDERGROUND SERVICE TOLL REMBAR;A800 MARK BY DATE APPR. DATE ST grF CA\FpRwP E O6 � > F OF \F O La Quint', California 92253 SECTION i, T.5.5., R.7E., S.B,M. CAS Phone: (760) 899 -5894 DRAWN BY: GM PLOT DATE: tt /72/o4 FOR: W.O. COUNTY 227 - 2600 TWO WORKING DAYS BEFORE YOU DIG. ARCHITECT REVISIONS COUNTY R COMMENDED Fax: (760)564-7535 CHECKED BY: DWG: LAGUNA SECA, LLC 080804 FILE NO. NOTE: Nam 5A 3/4" Palms _ _-- --- 4A 4 AVENUE 41 1 3/4" Drip mm 8° a 0 SECTION o• o $0 a° °000 g 5 o o ° 1. 10" ROUND VALVE BOX WITH BOLT DOWN LID. Install stainless steel bolt, washer and nut. Color: Tan in planters. Green in turf. HEAT BRAND "BV" ON BOX LID. 1" HIGH LETTERS. Carson Model #910 2. FINISH GRADE. 3, FULL FLOW, BRASS BODIED BALL VALVE- FULL PORT 4. SCH. 40 PVC PIPE EXTENSION, DIA. TO ALLOW FOR MOVEMENT OF HANDLE ON VALVE LENGTH AS REQUIRED. 5. 3/4" CRUSHED ROCK - 8" DEPTH. 6. COMMON BRICK (2 REQUIRED). 7. SCH. 80 NIPPLE TOE W /SS PVC COUPLING 8, 2" CLEARANCE. 9, PVC MAIN LINE PIPE. * 3/4" IN TURF AREAS. 2" IN SHRUB AREAS. FINISH GRADE 12 INCH SCHEDULE 80 PVC RISER MAINTAIN 3 INCHES ABOVE 2 - 1/2 INCH MARLEX FINISH GRADE STREET ELLS EMITTE f BUBBLER , --) 3" MIN PVC TEE SCH. 40 PVC LATERAL LINE OR ELBOW LINE SIZE LINE SIZE �j BALL \/AL\/E FD N.T.S. F SLIP BASE SOCKET OVER END WINS NOTE: WORK CONTAINED WITHIN THESE PLANS SHALL NOT COMMENCE UNTIL AN ENCROACHMENT PERMIT AND /OR A GRADING PERMIT HAS BEEN ISSUED. Important Notice - Underground Service Alert oae SECTION 42164217 OF THE GOVERNMENT CODE REQUIRES A DIG ALERT IDENTIFICATION NUMBER BE ' ISSUED BEFORE A 'PERMIT TO EXCAVATE' WILL BE VAL FOR YOUR DIG ALERT IDENTIFICATION NUMBER CALL .UNDERGROUND SERVICE ALERT TOLL FREE AT 1 -800- 227 -2600 TWO WORKING DAYS BEFORE YOU DIG. TRENGH I N6; N.T.S. LEGEND O NON- PRESSURE LATERAL LINE PIPING. O2 PRESSURE MAIN LINE PIPING O3 CONTROL WIRES - TAPE AND BUNDLE EVERY 10 FEET. INSTALL ADJACENT TO PRESSURE MAIN LINE. ® PROVIDE 2" DEPTH OF CLEAN BACKFILL. O SEE IRRIGATION SPECIFICATIONS FOR BACKFILL AND COMPACTION REQUIREMENTS. �6 FINISH GRADE. * MINIMUM BACKFILL DEPTHS FROM FINISH GRADE TO TOP OF MAINLINE 24" FOR PIPE SIZES 3" AND LARGER 18" FOR PIPE SIZES 2 1/2" AND SMALLER. LEGEND PALK TREE WA if'EG° ONQ DE AOL NO-SCALE O RAINBIRD BUBBLER. U3 PVC RISER — SCH. 80 .ATERAL PER PLAN. PIT PER PLANTING DETAILS. GRADE OR PALM ROOT BALL OR PALM TRUNK ?N UNDISTURBED NATIVE SOIL EX 90 DEG. STREET ELL. JOINT EM OT TER 0 BU ASSEMBLY N.T.S. NOTE, FOR WIRE SIZES No. 14, NO. 12 and No. 10. 7 7TRIf WIRES APPROXIMATELY 5/8' FROM END. TWIST ENDS TOGETHER STEP I APPLY SEALER TO OUTSIDE OF SEALING PLUG. FILL CAVITY WITH SEALER PUT CRIMP SLEEVE OVER WIRE ENDS, CRIMP SLEEVE AND CUT OFF EXCESS WIRE. STEP 2 PULL BASE SOCKET OVER WIRE END AS FAR AS POSSIBLE. PUSH SEALING PLUG INTO BASE SOCKET. STEP 3 -- PUSH WIRES TO END OF BASE SOCKET TO ASSURE COMPLETE SEALING OF CONNECTION. RAINBIRD PEN -TITS WIRE CONNECTOR STEP 4 12 12" MAX. O 6" PLASTIC ROUND VALVE BOX. HEAT BRAND "QC" ON LID IN 1" HIGH. Color: Tan in planters. Green in turf. 'Carson' Model 708 Econo O FINISH GRADE. 0 ® 3/4" CRUSHED ROCK, 6" DEPTH. O BRASS NIPPLE. © BRASS 90 DEG. ELL. O MAIN LINE PIPING. OS MAIN LINE FITTING. �q BRASS 90 DEG. STREET ELL. 10 BRASS NIPPLE - 6" LONG. II QUICK COUPLING VALVE. 12 WALK OR CURB. * 1" IN LAWN AREAS. 2" IN SHRUB AREAS. NOTE: USE TEFLON TAPE ON ALL MALE PIPE THREADS. WORE DONNE C TO OO IN�I DD ESL ARL G2U I GK GOUFLER NO-SCALE N.T.S. OUTSIDE 'CARSON 1419 -12 STANDARD PLASTIC VALVE BOX �- WALL BRAND LID 'RCV' - LETTERS 2' HIGH BOX COLOR Green In Turf / Tan In Planters Solt down Ild with Stainless Steel Bolt, Washer and Nut. O ELECTRICAL JUNCTION BOX size as required I'MRR BELOW LID FINISH GRADE O RAINBIRD CONTROLLER — WALL MOUNTED 1' MK M OW LID Z p CONTRACTOR TO PROVIDE LAMINATED COLOR CODED MAP LOCATED & SECURED INSIDE (e.g. Sta. 1 — Tree Drip, Sta. 2 — Turf Curb) L CONDUIT — SCH. 40 PVC ELECTRIC VALVE O4 90 Degree PVC Sweeps LINE SIZE 1 120 VOLT INPUT O �F NI5HL6 C� JII'y� 80d ELL -PVC SCHEDULE 40 CI 6 . 6' SdEDULE 80 PVC NIPPLE SCHEDULE 80 PVC NIPPLE ° GALVANIZED OR - 3/4 INCH GRAVEL SUMP BRASS UNION 2 CUBIC FEET CONTROL WIRE MAIN SUPPLY LINE CONNECT TO CONTROLLER MAIN LINE FITTING TO SPRINKLERS REMOTE CONTROL VALVE NO-SCALE c SEAL COUNTY COUNTY OF RIVERSIDE �p(,OFESSIO � TRANSPORTATION DEPARTMENT A ' 0 T Fyn._ APPROVED BY: ARCHITECT I REVISIONS No /06 Ezp. 6/30/06 R 33950 OT EX —O6 DATE 'R. DATE STglF OF CWVW o °°2 t4 !J COUNTY MMEND_0 - 09 AT tf 'U 5 Q 9�F OF CAV�F��= DROP CONTROL VALVE J ! NO-SCALE LEGEND 1. FINISH GRADE. 2. PVC PIPE (DEPTH PER DETAIL). 3. RAIN BIRD MODEL # XCZ XERIGATION CONTROL ZONE ASSEMBLY. 4. WIRE CONNECTOR. } 5. PILOT WIRE. 6. COMMON WIRE. 7. 3/4" CRUSHED ROCK. III 8. (4) 2" x 4" x 12" PRESSURE TREATED WOOD FOR SUPPORT. 9. 12" x 18" RECTANGULAR PLASTIC VALVE BOX. Color: Tan in planters. Green in turf. I Carson Model #1419 -12 I 10. PVC UNION(THREADED) FOR SERVICING ASSEMBLY, 11. RECTANGULAR VALVE BOX WITH BOLT DOWN COVER. Install stainless steel bolt, washer and nut. HEAT BRAND VALVE STATION N0, ON LID IN 1" HIGH CHARACTERS. Carson Model #1419 -12 Color: Tan in planters. Green in turf. 12. COIL WIRE PER SPECIFICATIONS LEGEND NOTES: 1. Common wire to be white and control wire to be black unless otherwise noted. 2. No splices shall be made between controller and remote control valves unless otherwise noted. 3. All exposed wire to be installed in conduit. 4. Control wire to be minimum AWG ##14, one control wire to each controller, controller to be grounded as per manufacturers specifications. 5. 120 volt power to be provided by others, all shall be according to local code. 6. Contractor will connect cotroller to power source and supply labor, equipment & material needed for said connection. Owner to supply power. Contractor to field verify location of power source prior to submitting Bid. Install per local code. N.T.S. GM FUTURE DESIGNS Landscape Design Services 81390 Golf View Drive La Quinta, California 92253 Phone: (760) 899 -5894 Fax: (760)564 -7535 BENCH MARK: TRACT NO. 30866 - I.P. NO. 030131 SHEET NO. COUNTY OF RIVERSIDE L-3 IRR/%j/_1 DETAILS A PORTION OF NORTH 'AEI /4 AND THE 5EI /4 OF 3 DESIGN BY: GM SCALE: AS NOTED SECTION T, T.5.5., R.1E., 5.5.M. OF SHTS DRAWN BY: GM PLOT DATE: 11112104 FOR: W.O. COUNTY CHECKED BY: DWG: LAGUNA SECA, LLC 080804 FILE NO. zM