Loading...
962v_sgC 0 U N T Y O F R I V E R S I D E INDEX OF SHEETS SOLAR-POWERED SPEED FEEDBACK SIGNS SHEET No. DESCRIPTION 1 TITLE 2 LAYOUT LOCATION #1 EL SOBRANTE RD (NORTH OF CAJALCO RD) LOCATION #2 CAJALCO RD (WEST OF HOLLIS LN) LOCATION #1 SAN TIMOTEO CYN RD (BETWEEN LIVE OAK CYN RD & REDLANDS BLVD) LOCATION #4 SOBOBA RD (WEST OF SAN JACINTO CITY LIMITS) LOCATION #5 VAN BUREN BLVD (SOUTH OF MOCKINGBIRD CYN RD) FEDERAL AID No. HSIPL -5956 (218) TO BE SUPPLEMENTED BY CALTRANS STANDARD PLANS DATED 2010 AND COUNTY OF RIVERSIDE ROAD IMPROVEMENT STANDARDS DATED 12 -20 -2007 COUNTY OF SAN BERNARDINO ff BEAUMONT COUNTY OF RIVERSIDE COUNTY OF ORANGE BANNING HEMET TEMECULA y_1XT1 .'19 :1 11V eL INDIO INDIAN COACHELLA WELLS SALTON SEA COUNTY OF SAN DIEGO LOCAL I COUNTY OF IMPERIAL I VICINTY MAP LOC #1 T4S, R5W SECT 11 LOC #2 T4S, R5W, SECT 17 LOC #3 T2S, R2W, SECT 14 LOC #4 T4S, R1 W, SECT 23 LOC #5 TS3, R5W, SECT 28 DIG ALERT Don't Dig ... Until You Call U.S.A. Toll Free REV BY 011 -227 -2000 Tcl, FCR T HE LOCATICN CF BURIED UTILITY LINES DON'T DISRIPT VITAL SERVICES I TWO WORKING DAYS BEFORE YOU DIG I BORDER REVISED 08/01/2013 ; ]Willi STATE OF ARIZONA GENERAL NOTES 1. ALL MATERIAL AND WORK SHALL CONFORM TO THE 2010 EDITION OF CALTRANS STANDARD PLANS AND STANDARD SPECIFICATIONS, COUNTY OF RIVERSIDE STANDARD PLANS EFFECTIVE 12 -20 -2007, AND THE CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES 2012 (CA MUTCD 2012). 2. THE CONTRACTOR SHALL NOTIFY UNDERGROUND SERVICE ALERT, (811) 227 -2600 AND ALL CONCERNED UTILITY COMPANIES AT LEAST TWO WORKING DAYS IN ADVANCE OF EXCAVATION. LOCATIONS OF ALL UNDERGROUND UTILITIES ARE APPROXIMATE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATIONS AND VERIFY ALL CONDITIONS ON THE JOB SITE PRIOR TO COMMENCING WORK. THE CONTRACTOR IS FULLY RESPONSIBLE FOR ALL DAMAGES OCCURRED DUE TO FAILURE TO LOCATE AND PRESERVE ALL UNDERGROUND UTILITIES. HAND DIG AS NEEDED OR AS DIRECTED BY ENGINEER UNTIL CLEAR OF OBSTRUCTIONS. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY CLEAN UP ON COUNTY RIGHT -OF -WAY AFFECTED BY CONTRACTOR'S WORK. THE CONTRACTOR SHALL KEEP COUNTY RIGHT -OF -WAY CLEAN OF DEBRIS, WITH DUST AND OTHER NUISANCES BEING CONTROLLED AT ALL TIMES. METHOD OF STREET CLEANING SHALL BE DRY SWEEPING OF ALL PAVED AREAS. THERE SHALL BE NO STOCKPILING OF CONSTRUCTION MATERIALS WITHIN THE COUNTY RIGHT -OF -WAY WITHOUT THE PERMISSION OF THE ENGINEER. 4. SEE CALTRANS STANDARD PLAN ES -1A, ES -1B, AND ES -1C FOR SYMBOLS AND ABBREVIATION LEGENDS. TITLE SOLAR- POWERED SPEED FEEDBACK SIGNS AT DATE VARIOUS LOCATIONS NO SCALE WO C3 -0086 V) Z c� 4 aM O LU w w W Z ¢ J N � c ¢ 0 CZ O ti L / E o E¢ U t M c z Q U J ¢ m r o 0 v w v w GENERAL SIGNING NOTES 1. ALL MATERIAL AND WORK SHALL CONFORM TO THE 2010 EDITION OF CALTRANS STANDARD PLANS AND STANDARD SPECIFICATIONS, COUNTY OF RIVERSIDE STANDARD PLANS EFFECTIVE 12 -20 -2007, AND THE o CALIFORNIA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES 2012. k4 o 2. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL SIGNS IN ACCORDANCE WITH THE PLANS AND AS DIRECTED BY THE ENGINEER. 3. THE CONTRACTOR SHALL INSTALL STANDARD SIZE SIGN PANEL ON 2" SQUARE PERFORATED STEEL TUBE POST WITH TWO PIECE ANCHOR AND SLEEVE. FASTENED WITH %" RIVETS WITH STAINLESS STEEL o WASHERS, UNLESS OTHERWISE NOTED. THE EXACT LOCATION OF ALL SIGNS SHALL BE DETERMINED IN THE FIELD BY THE ENGINEER. 4. THE CONTRACTOR SHALL REMOVE SIGNS IN ACCORDANCE WITH THE PLANS AND AS DIRECTED BY THE ENGINEER. THE CONTRACTOR SHALL DELIVER REMOVED SIGNS TO THE COUNTY YARD OR AS DIRECTED BY THE ENGINEER. 5. THE CONTRACTOR SHALL LAYOUT THE PROPOSED SIGNING IN ACCORDANCE WITH THE PLANS AND OBTAIN THE ENGINEER'S APPROVAL PRIOR TO ACTUAL INSTALLATION. TITLE SOLAR- POWERED SPEED FEEDBACK SIGNS AT DATE VARIOUS LOCATIONS NO SCALE WO C3 -0086 V) Z c� 4 aM O LU w w W Z ¢ J N � c ¢ 0 CZ O ti L / E o E¢ U t M c z Q U J ¢ m r o 0 v w v w I SHEET 1 OF 2 COUNTY ML A FILE NO. SHEET No. o r o a M U o a I SHEET 1 OF 2 COUNTY ML A FILE NO. LOCATION #1 EL SOBRANTE RD EXIST R6(55)(CA)QQ - --'< STA 61 +39 W1 - 2(R),W1 3 -1 (50) W1 - 2(R),W1 3 -1 (50) STA 35 +23 STA 31+85 NOT TO SCALE 1 -8(L) 7 -EACH 1 -8fl 7 -EACH 1 -8 L 7 -EACH F END STA 28 +3 SPACED AT 80 CAJALCO RD •:•_ C� R2 -1(55) STA 1 1 +95&_-PA I O� BORDER REVISED 08/01/2013 TA 14 +95 STA 20 +00 EXIST R2 -1(55) RELOCATE FROM STA 17 +80 TO STA 13 +00 EXIST W1- 2(L),W13 -1(50) RELOCATE FROM STA 14 +45 TO STA 16 +50 / Q c� 1 -4(L) TA 49 +30 NOT TO SCALE 1 -2(R) TA 61+30 2 -1(55) 0 +95 �P TA 66 +95 NOT TO SCALE LOCATION #2 CAJALCO RD EXIST R2 -1(55 STA 5 +80 EXIST R2 -1(55) 1 STA 13 +10 END STA 66 +20 SPACED AT 100' o z 1 EXIST R2 -1(55) STA 77 +45 BEG STA W1- 2(L),W13 -1 (40) 8 \ STA 72 +97 W1 - 2(L),W1 3 -1 (40) 2 STA 72 +97 C os STA 69 +00 7 W1 -8fl 6 -EACH W1 -8 L 6 -EACH PHASE DIAGRAM HEIGHT SIG MA USED 18 -4 -100 17' 01 02 03 04 USED W1 -4(L ) U ED USED 36" 05 06 1 07 08 CYN ROAD DETAIL "B" KINDER MORGAN 20" PETROLEUM PIPELINE NOT TO SCALE LOCATION #3 SAN TIMOTEO CYN RD R2 -1(55) STA 13 +00 SEE DET W1- 2(L) -1(50) STA 37 +45 W1- 2(L) 3 -1 (50) STA 37 +45 W1 -8(L) 3 -EACH NOT TO SCALE 7 STA 50 +50 2 STA252 +'W53 -1 (50) 8 STA2(R)'Wl3 -1(50) -. - - -- -EXIST ALL -WAY STOP CYN ROAD IST R2 -1(55) A 66 +77 CONSTRUCTION NOTES (1 PROTECT EXISTING SIGN AND POST IN PLACE. I22 FURNISH AND INSTALL SIGN ON NEW 2" SQUARE PERFORATED STEEL TUBE POST. RELOCATE EXISTING SIGN ON NEW 2" SQUARE PERFORATED STEEL TUBE POST. ® REMOVE AND SALVAGE EXISTING STANDARD AND DELIVER TO THE COUNTY MAINTENANCE YARD AT 2950 WASHINGTON STREET RIVERSIDE AS DIRECTED BY THE ENGINEER. REMOVE TOP 12" OF FOUNDATION AND BACKF'ILL WITH NATIVE MATERIAL. Q5 FURNISH AND INSTALL FULL - MATRIX CHANGEABLE MESSAGE SIGN ON TYPE 18 -4 -100 STANDARD WITH 30'MAST ARM PER CALTRANS STANDARD PLANS ES -7F AND DETAIL "A ". CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIAL AND CONNECTIONS TO ATTACH THE DISPLAY BOARD TO THE STANDARD WITH A PELCO BRACKET ASSEMBLY OR APPROVED EQUAL PER THE MANUFACTURES REQUIREMENTS FOR THE INTENDED OPERATION. FINAL POLE LOCATION SHALL BE APPROVED BY THE ENGINEER. CONTRACTOR SHALL KEEP THE EXISTING FLASHER IN OPERATION UNTIL THE NEW SYSTEM IS FULLY FUNCTIONING. © INTERCEPT EXISTING 1.5" CONDUIT AND INSTALL NEW #5 PULL BOX. PROTECT EXISTING 4 #10 CONDUCTORS AND PROVIDE 5' OF SLACK IN NEW PULL BACK. INSTALL 2" CONDUIT AND 4 #10 CONDUCTORS FROM NEW PULL BOX TO NEW POLE. 07 FURNISH AND INSTALL SOLAR POWERED DYNAMIC VARIABLE SPEED WARNING DISPLAY BOARD ON TYPE 1 -A (14') STEEL POLE PER CALTRANS STD PLANS ES -76 AND COUNTY STD 1210. CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIAL AND CONNECTIONS TO ATTACH THE DISPLAY BOARD TO THE TYPE 1 -A POLE PER THE MANUFACTURER'S REQUIREMENTS FOR THE INTENDED OPERATION. FINAL POLE LOCATION SHALL BE INSTALLED PER COUNTY STANDARD NO. 820 OR AS DIRECTED BY THE ENGINEER. REMOVE AND SALVAGE EXISTING SIGN AND POST. t�9 REPLACE EXISTING 170E CONTROLLER UNIT WITH NEW 2070E CONTROLLER UNIT. PROGRAM NEW 2070E CONTROLLER UNIT TO OPERATE DYNAMIC VARIABLE SPEED WARNING DISPLAY BOARD SEQUENCE PER LOCATION #5 NOTES 1 -4. 10 REMOVE EXISTING PULL BOX AND ABANDON EXISTING CONDUIT IN PLACE. SIGN SIZES APPROXIMATELY 830' TO CENTERLINE MOCKINGBIRD CYN RD APPROXIMATELY 840' TO CENTERLINE MOCKINGBIRD CYN RD POLE SCHEDULE No. TYPE HEIGHT SIG MA QA 18 -4 -100 17' 30' DYNAMIC VARIABLE SPEED WARNING DISPLAY BOARD SEQUENCE: 1. DISPLAY MESSAGE 3 SECONDS PRIOR TO THE TERMINATION OF PHASE SIX GREEN INTERVAL. QROFESSIpN 2. DISPLAY MESSAGE THE FULL DURATION OF PHASE SIX YELLOW INTERVAL. ( ((NN o . - 3. DISPLAY M ESSAGE THE FULL DURATION OF PHASE SIX RED INTERVAL. IOMLING TSAI 52870 4. DISPLAY MESSAGE VARIABLE UP TO SIX SECONDS AFTER PHASE SIX GREEN INTERVAL BEGINS. RELATIVE BORDER SCALE IS IN INCHES m 00 F- v� z J V) 0 �STA254 +85 3 -1 (40) STA 58 +40 7 8 W1- 2(R),W13 -1(40) STA 54 +85 LOCATION #5 VAN BUREN BLVD 0 1 2 3 R2-1(55) 36" X 48" W1 -2(L ) 36" X 36" W1 -2(R ) 36" X 36" W1 -4(L ) 36" X 36" W1 -8 L) 30" X 36" W1 -8 R 30" X 36" W13-1(40) 30" X 30" W13 -1 50 30" X 30" INSTALL BOTTOM OF SIGN 5 ABOVE GRADE DESIGNED BY epcanvcn Pty- DOWLIN TSAI PROJECT MANAGER COUNTY OF RIVERSIDE USERNAME = >mkrantz DGN FILE =>C3 -0086 ea L- 01.SHT LEGEND: o CMS CHANGEABLE MESSAGE SIGN SHEET No. LAYOUT SOLAR- POWERED SPEED FEEDBACK SIGNS AT DATE VARIOUS LOCATIONS . �� / Lml SCALE • I =80 SHEET 2 OF 2 WO C3 -0086 COUNTY FILE o. 0 J 0 0 0 / Z N J C a uZ o� Lo Y F a U ow M Y LJ a m �o Q W W Q� �o N m I Q > a M I � a�