895xx_wtRANCH CALIFORNIA WATER DISTRICT (RCWD) GENERAL CONSTRUCTION NOTES COUNTY OF RIVERSIDE PARCEL MAP 25962 AND 25963 CORTE FUENTES WATER LINE IMPROVEMENTS I. GENERAL 3. UTILITIES A. CONTRACTOR SHALL FURNISH AND INSTALL ALL FACILITIES IN ACCORDANCE WTTH A. AT LEAST 48 HOURS BEFORE COMMENCING ANY EXCAVATION, CONTRACTOR SHALL RANCHO CALIFORNIA WATER DISTRICT'S (RCWD/DISTRICT) STANDARD SPECIFICATIONS AND REQUEST UNDERGROUND SERVICE ALERT (1-800-422-4133) AND NON-MEMBER STANDARD DRAWINGS FOR WATER AND SANITARY SEWFFR FACILITIES (LATEST REVISION), COMPANIES, OR UTILITIES TO MARK OR OTHERWISE INDICATE THE LOCATION(S) OF THEIR THE SPECIFICATIONS AND STANDARD DRAWINGS ARE AVAILABLE FROM THE DISTRICT'S WEB SUBSURFACE FACILITIES INCLUDING, BUT NOT LIMITED TO, STRUCTURES INCLUDING SITE AT WWW.RANCHOWATER,COM, CONTRACTOR SHALL BE IN POSSESSION OF DISTRICT'S VAULTS, MAIN CONDUCTORS OR CONDUITS, AND SERVICE. CONNECTIONS. SPECIFICATIONS AND STANDARD DRAWINGS ON THE JOB SITE AT ALL TIMES. B. ALL PERMITS REQUIRED BY LAW SHALL BE ACQUIRED BY THE B. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL EXPOSE EXISTING WATERLINES AT PROPOSED CONNECTIONS AND CROSSING AND VERIFY ELEVATIONS, LOCATION, AND DEVELOPER/APPLICANT OR THEIR CONTRACTOR. SIZE OF EXISTING FACILITIES. C. ALL CONSTRUCTION SHALL CONFORM TO CURRENT CAL OSTIA SAFETY C. CONTRACTOR SHALL NOT INTERRUPT OR DISTURB ANY UTILITY FACILITY WITHOUT REQUIREMENTS. AUTHORITY FROM THE UTILITY COMPANY, WHERE PROTECTION IS REQUIRED TO ENSURE D. APPROVAL BY RCWD IMPLIES NO PERMISSION OTHER THAN THAT WITHIN THE DISTRICT'S INTEGRITY OF UTILITY FACILITIES (I1'�CLUDING DISTRICT -OWNED UTILITIES), CONTRACTOR SHALL FURNISH AND PLACE ALL NECESSARY PROTECTION. JURISDICTION. REQUIREMENTS OF RCWD SHALL TAKE PRECEDENCE OVER REQUIREMENTS OF OTHER AGENCIES ONLY WHEN RCWD REQUIREMENTS ARE MORE STRINGENT. 4. CONSTRUCTION DRAWINGS E. CONTRACTOR SHALL NOTIFY RCWD'S CONSTRUCTION CONTRACTS MANAGER A A, MINIMUM PIPE COVER SHALL BE 48" FROM FINISHED GROUND SURFACE. MINIMUM OF ONE WEEK PRIOR TO STARTING CONSTRUCTION. A PRFCONSTRUCTION MEETING WILL NOT BE SCHEDULED UNTIL ALL ITEMS IN THE DEVELOPER'S INSPECTION B. WATER SYSTEM PROFILE ELEVATIONS ARE TO FLOW LINE OF PIPE. PACKAGE HAVE 13EEN SUBMITTED TO AND APPROVED BY RCWD. A MINIMUM OF ONE WEEK IS REQUIRED FOR REVIEW AND APPROVAL. C. STATIONING FOR PIPELINE AS SHOWN ON PLAN PORTION OF DRAWINGS IS F. CONTRACTOR SHALL PROVIDE WRITTEN NOTIFICATION TO THE RCWD CONSTRUCTION PERPENDICULAR TO CENTERLINE OF RIGHT-OF-WAY, CONTRACTS MANAGER REQUESTING A SYSTEM SHUTDOWN FOR CONNECTION TO D. STANDARD UTILITY LOCATIONS SHALL BE PER RIVERSIDE COUNTY STANDARD NO, EXISTING SYSTEM. SAID NOTIFICATION SHALL BE MADE A MINIMUM OF THREE WEEKS PRIOR 817 AND TITLE 22, §W72 FOR PROJECTS THAT CANNOT MEET SF.PARATTON TO SAID SHUTDOWN. REQUIREMENTS BETWEEN POTABLE AND NON -POTABLE PIPELINES. RCWD STANDARD G. CONTRACTOR SHALL DESIGNATE A QUALIFIED SUPERINTENDENT WITH FULL AUTHORITY DRAWING S-23 AND DEPARTMENT OF HEALTH SERVICES' GUIDANCE MEMO NO, 2003-2 MAY BE USED ONLY WITH WRITTEN APPROVAL FROM THE STATE WATER RESOURCES TO ACT ON BEHALF OF THE CONTRACTOR. SAID SUPERINTENDENT SHALL CONTROL BOARD. BE ON THE .FOB SITE AT ALL TIMES. H. CONTRACTOR SHALL PERFORM ALL WORK UNDER RIVERSIDE COUNTY ROAD E. THE COORDINATES SHOWN ON THESE PLANS ARE IN THE NORTH AMERICAN DATUM 1983, STATE PLANE, CALIFORNIA ZONE 6 COORDINATE SYSTEM, DEPARTMENT, CITY OF TEMECULA, OR CITY OF MURRIETA JURISDICTION IN ACCORDANCE WITH ALL REQUIREMENTS OF SAID DEPARTMENT OR CITY INCLUDING TRAFFIC CONTROL, F. PURSUANT TO 16 CALIFORNIA CODE RFGULATIONS 404,1., NO FIELD CHANGES TO PAVEMENT REMOVAL, TEMPORARY PAVEMENT PLACEMENT, PERMANENT PAVEMENT THE CONSTRUCTION DRAWINGS ARE PERMITTED WITHOUT TIIE RESPONSIBLE CHARGE PLACEMENT (INCLUDING BASE MATERIAL) AND TEMPORARY AND PERMANENT TRAFFIC OF A REGISTERED CIVIL ENGINEER THROUGH THE PROCESS IDENTIFIED IN SECTION II.D. OF STRIPING. RCWD'S WATER SYSTEM FACILITY REQUIREMENTS AND DESIGN GUIDELINES (LATEST VERSION). RCWD INSPECTION AND ENGINEERING STAFF HAVE NO AUTHORITY TO 1. APPROVAL OF THESE PLANS IS VALID FOR ONE YEAR FROM THE DATE THEY WERE SIGNED APPROVE FIELD CHANGES WITHOUT THE PRIOR STAMPED AND SEALED REVISIONS BY RCWD, APPROVED BY THE ENGINEER OF RECORD OR A SUCCESSOR ENGINEER. ALL WORK DONE 2. PIPELINE AND APPURTENANCES IN VIOLATION OF APPROVED PLANS SHALL BE EXCAVATED AND REMOVED AT THE CONTRACTOR'S SOLE EXPENSE. A. ALL VALVES, PIPING, AND APPURTENANCES SHALL BE DESIGNED TO MEET OR 5, CONSTRUCTION TOLERANCES EXCEED THE SPECIFIED MINIMUM DESIGN PRESSURE SHOWN ON THE PLANIPROFILE SHEETS. IN ADDITION, ALL VALVES, PIPING, AND APPURTENANCES SHALL BE TESTED AT PIPELINES SHALL BE CONSTRUCTED SO THAT ACTUAL FLOW LINE ELEVATIONS ARE A PRESSURE OF 10% OVER SAID MINIMUM DESIGN PRESSURE,. VALVES SHALL BE WITHIN 0.1 FOOT OF DESIGN FLOW LINE ELEVATIONS. PIPELINES, WHEN INSTALLED, CAPABLE OF WITHSTANDING SAID TEST PRESSURE IN A CLOSED POSITION, SHALL HAVE CONTINUOUS UPGRADE OR DOWNGRADE, CORRESPONDING WITH DESIGN SLOPE, WITHOUT ANY HIGH SPOTS. PIPELINES SHALL BE CONSTRUCTED SO THAT B. ALL MATERIALS, TESTING AND INSPECTION OF PIPE SHALL BE IN CONFORMITY WITH THE ACTUAL PIPELINE CENTERLINES ARE WITHIN 0,1 FOOT OF DESIGN PTPELTNE REQUIREMENTS OF RANCHO CALIFORNIA WATER DISTRICT, RIVERSIDE COUNTY, CITY OF CENTERLINES. TEMECULA, CITY OF MURRIETA, AND/OR THE AMERICAN WATER WORKS ASSOCIATION STANDARDS. FAILURE TO MEET ANY REQUIREMENTS OF THE ABOVE REFERENCED PIPELINE CONSTRUCTION SHALL CONFORM WITH CONSTRUCTION DRAWINGS IN ENTITIES WILL BE CAUSE FOR REJECTION. ACCORDANCE, WITH THE ABOVE SPECIFIED TOLERANCES, CONTRACTOR SHALL ASSIST DISTRICT AS REQUIRED TO CONFIRM COMPLIANCE WITH CONSTRUCTION TOLERANCES. C. PIPE SHALL BE 6" OR 8" AWWA C900 DR-14 FOR PVC AND 8" CML&C 1 /4" CONTRACTOR SHALL MAKE OR ASSIST IN MAKING ALL NECESSARY MEASUREMENTS AS WALL FOR STEEL PIPE, DETERMINED BY DISTRICT. D. VALVES 12" AND SMALLER SHALL BE RESILIENT SEATED GATE VALVES UNLESS OTHERWISE SPECIFIED, VALVES 16" AND LARGER SHALL BE BUTTERFLY VALVES UNLESS OTHERWISE SPECIFIED. VALVES SHALL BE INSTALLED IN ACCORDANCE WITH RCWD STANDARD DRAWING NOS. RW-30 AND RW-3I. E, AIR VACUUM AND AIR RELEASE ASSEMBLIES SHALL BE INSTALLED IN ACCORDANCE WITH RCWD STANDARD DRAWING NO, RW-9, F. ALL SERVICES CONNECTION SHALL BE 1 " COPPER SERVICES BY 1" METER OR AS NOTED ON THE DRAWING. ALL SERVICES SHALL BE LOCATED AS SHOWN ON THE DRAWINGS AND/OR AS DIRECTED BY RCWD INSPECTOR TO MISS DRIVEWAYS U AND OTHER IMPROVEMENTS, SERVICE CONNECTIONS SHALL BE INSTALLED IN ACCORDANCE 1 WITH RCWD STANDARD DRAWING NO. RW-13. Li N o ALL COMMERCIAL, INDUSTRIAL, MULTIFAMILY, LARGE LOT, OR LANDSCAPE IRRIGATION Q \ z METERS SHALL BE INSTALLED WITH A DISTRICT APPROVED BACKFLOW DFVTCF RCW Q STANDARD DRAWING NO, RW-18 OR RW-19 U7 p G. FIRE HYDRANTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH STANDARD w < DRAWING NO (S). RW-1 A, RW-8, RW-26 AND RW-24A. UNLESS OTHERWISE SPECIFIED. THE m PRESSURE CLASS OF THE PIPE SELECTED FOR THE FIRE LATERAL SHALL BE THE SAME Z AS THE MAIN IT IS CONNECTED TO. z /3 U7 H. WATER PIPELINE CONSTRUCTION SHALL BE IN ACCORDANCE WITH STANDARD DRAWING z NO(S). RW-22, RW-24 AND RW-26B FOR PVC PIPE AN RCWD STANDARD O DRAWING NO(S), RW-25, RW-26A, RW-29 AND RW-32 THROUGH RW-36 FOR CML & C I- Z STEEL PIPE. 6. INSPECTION DEPOSIT THREE WEEKS PRIOR TO CONSTRUCTION, DEVELOPER/APPLICANT SHALL MAKE A DEPOSIT FOR INSPECTION. INSPECTION DEPOSITS ARE BASED UPON ESTIMATES. SHOULD ACTUAL COSTS BE GREATER, THE BALANCE SHALL BE PAID TO THE DISTRICT BY THE APPLICANT, SHOULD ACTUAL COSTS BE LESS, THE BALANCE SHALL BE REFUNDED TO THE APPLICANT. FEES/DEPOSITS ARE SUBJECT TO CHANGE WITHOUT NOTICE. 7. ENGINEERING FIRM PRIOR TO SIGNING OF WATER CONSTRUCTION DRAWINGS BY RCWD, ALL QUESTIONS CONCERNING THIS PROJECT SHALL BE DIRECTED TO: MASSOUD GHIAM PE NO, C59993 LAKESHORE ENGINEERING BASIS OF BEARING CENTER LINE OF CORTE FUENTES AS SHOWN ON PARCEL MAP 25962 Q %a r* -) OU 1. THRUST RESTRAINT SHALL BE A.P.N. NUMBERS PROVIDED BY WELDED .JOINTS OR MECHANICAL JOINT RESTRAINTS. IF CONCRETE THRUST BLOCKS ARE ALLOWED BY RCWD, THRUST BLOCKS PARCEL MAP 25962 O J SHALL BE CONSTRUCTED IN ACCORDANCE WITH RCWD STANDARD DRAWING NO. RW-26 PARCEL 1 932-350-012 ry WI WITH ALL BEARING AREA SIZES CALLED OUT ON THE PLANS, PARCEL 2 932-350-037 Q PARCEL 3 932-350-013 U PARCEL 4 932-350-014 J n n PARCEL MAP 25963 z Q BENCH MARK: PARCEL 2 932-350-036 PARCEL 4 932-350-018 z Elevation= ELEVATION:1,933.00 NAD 83/NAVD 88 BENCHMARK# RIVERSIDE COUNTY Z7150 � Z ' U C� z RIVERSIDE COUNTY # Z 7150 v) < r NAD 83/NAVD 88 EPOCH 2O07 TENAJA ROAD NORTH OF SIERRA j O ELLENA (Dz gowNlmM� 3/4" LP W/RCFC TRI STA. PLUG FLUSH Cdmbmpmdi& O F 6,243,666.88 N= 2,136,784.55 U O BENCH MARK: E— ��gFESSZ0N co RIVERSIDE COUNTY 0 Z 7150 NAD 83/NAVD 88 OU D G EPOCH 2O07 �w44'� UI TENAJA ROAD NORTH OF SIERRA � U ELLENA w C 59993 U 3/4" IP W/RCFC TRI STA. PLUG FL.USII a FXP.6-30-2022 O O E=,6,243,666.88 U Q N=2,136,784.55 `�� crv1L4 � Q CL GPS EL: 1,933,00 O� CAS��O4 REV. DATE, BY DESCRIPTION WATER SYSTEM CERTIFICATE ABBREVIATIONS (AS SHOWN ON THE PLANS) AC ASPHALT LF LINEAR FEET A.V.&A,R. AIR VACUUM AND AIR MAX MAXIMUM RELEASE MH MANHOLE ASS'Y ASSEMBLY MIN MINIMUM BC BEGIN CURVE N NORTH BO BLOW OFF NO NUMBER BOT BOTTOM N'TS NOT TO SCALE BW BACKWATER VALVE PUC PUBLIC UTILITY CDF CONTROLLED DENSITY FILL EASEMENT CL CENTER LINE PROP PROPOSED CML&C CEMENT MORTAR LINED PSI POUNDS PER SQUARE & COATED STEEL PIPE INCH CMP CORRUGATED METAL PIPE RCP REINFORCED CONCRETE CONST CONSTRUCT PIPE DI DUCTILE IRON PIPE RCWD RANCHO CALIFORNIA DWG DRAWING WATER DISTRICT E EAST ROW RIGHT OF WAY EA EACH R/W RIGHT OF WAY EC END CURVE S SOUTH E/P EDGE OF PAVEMENT S= SLOPE EX EXISTING SD STORM DRAIN EXIST EXISTING ST STREET F.H. FIRE HYDRANT STD STANDARD FL FLOWLINE W WEST FLG FLANGE WM WATER MAIN F FLANGE WM WATER METER GV GATE VALVE WO WORK ORDER GPM GALLONS PER MINUTE WTR WATERLINE HORZ HORIZONTAL X-ING CROSSING INV INVERT INST INSTRUMENT INT INTERSECTION LEGEND PROPOSED WATER LINE - W _ EXISTING WATER LINE EXISTING WATER VALVE, - 0 - CATV-- EXISTING CABLE TV -- - EXISTING FIRE HYDRANT PROPOSED FIRE HYDRANT LD-0 EXISTING AIR/AVC &AIR RELEASE. 30 PROPOSED AIR/AVC &AIR RELEASE EXISTING SURFACE OVER CL OF PIPE PROPOSED SURFACE OVER CL OF PIPE — .CL. ROAD CENTER LINE ---�-- — RIGHT - OF - WAY -r$—❑ PROPOSED I " COPPER WATER SERVICE ❑ WATER METER BOX EXISTING STORM DRAIN NOTIFICATIONS 1 • AT LEAST 48 HOURS PRIOR TO COMMENCING CONSTRUCTION, CONTRACTOR SHALL NOTIFY: A. UNDERGROUND SERVICE ALERT 1-800-227-2600 B. ALL PERMIT AGENCIES C. ALL OTHER AFFECTED UTILITIES: 1, COUNTY OF RIVERSIDE PUBLIC WORKS 2. RANCHO CALiFORNIA WATER DISTRICT (951) 296-6900 E, ANY OTHER CONTRACTING UTILITIES NOT USING USA F. LA CRESTA HOMEOWNER'S ASSOCIATION (H2O,A.) (951) 699-2918 G. RIVERSIDE COUNTY FLOOD CONTROL AND WATER CONSERVATION DISTRICT (RCFC & WCD) (951) 955-1266 I CERTIFY THAT THE DESIGN OF THE WATER SYSTEM IN UNINCORPORATED RIVERSIDE COUNTY IS IN ACCORDANCE WITH THE WATER SYSTEM MASTER PLAN OF RANCHO CALIFORNIA WATER DISTRICT AND THAT THE WATER SERVICE, STORAGE ANT) DISTRIBUTION SYSTEM WILL BE ADEQUATE TO SUPPLY WATER TO SAID PROJECT, THIS CERTIFICATION DOES NOT CONSTITUTE A GUARANTEE THAT IT WILL SUPPLY WATER TO SAID PROJECT AT ANY SPECIFIC QUANTITIES, FLOWS, OR PRESSURES FOR FIRE PROTECn7 OR ANY OTHER PURPOSE, ,r;0441NGINEERJNG MANAGER DATT� LAKESHORE ENGINEERING 24 OAKHURST RD IRVINE, CA 92620 TEL: (949) 307-5410 PREPARED BY PEN(). 59993 F 12-13-2022 MASSOUD GRIAM DATE: UNDERGROUND STRUCTURES Ld SI TE I' 15 w J� FRwY PALOMAR � � STREET Q CR qNp o f v A VeNUE T_ � Y ❑ O� w cA�LE' AVENIDA LA G\: Q SAN Ip p CRESTA r tiUFR,o LOCA iJON MAP NOT TO SCALE INDEX OF SHEETS SHEET NO. DESCRIPTION l TTT -E SHEET AND NOTES PLAN AND PROFILE FOR CORTE FUENTES OWNERIAPPLICANT ROY SALAMF.H RANCHO LA CRESTA PARTNERS LLC 3848 5TH AVENUE - SUITE "E" SAN DIEGO CA 92103 (760) 809-2887 ESTIMATE OF QUANTITIES DEVELOPER ROY SALAMFH RANCHO LA CRESTA PARTNERS LLC 3848 5TH AVENUE - SUITE "E" SAN DIEGO CA 92103 (760)809-2887 REMARK QTY, UNIT LEGEND DESCRIPTION STD. DWG. 635 LF 8" 0 C900 DR-14 PVC PIPELINE RW-22, R W-48 1" AIR VACUUM AND AIR RELEASE ASSEMBLY RW-]A, RW-9 RW-1 A, I EA 6" RESIDENTIAL FIRE HYDRANT ASSEMBLY RW-8, RW-26 RW-1A, 6 EA I" COPPER WATER SERVICE ASSEMBLY RW-13, RW-16 I EA 6" RESIDENTIAL FIRE HYDRANT ASSEMBLY RW-IA, RW-24A ALL UNDERGROUND UTILITIES OR STRUCTURES REPORTED BY OWNER OR OTHERS AND THOSE SHOWN ON THE RECORDS EXAMINED ARE INDICATED WITH THEIR APPROXIMATE LOCATION AND EXTENT. THE OWNER, BY ACCEPTING THESE PLANS OR PROCEEDING WITH IMPROVEMENTS, PURSUANT THERETO, AGREES TO ASSUME LIABILITY AND TO HOLD HARMLESS FOR ANY DAMAGE RESULTING FROM THE EXISTENCE OF UNDERGROUND UTILITIES OR STRUCTURES NOT REPORTED TO THE UNDERSIGNED, NOR INDICATED ON THE PUBLIC RECORDS EXAMINED, LOCATED AT VARIANCE WITH THAT REPORTED AS SHOWN ON RECORDS EXAMINED. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITIES OR STRUCTURES SHOWN AND ANY OTHER UTILITIES. RIVERSIDE COUNTY FIRE DEPARTMENT NOTE: ALL FIRE HYDRANTS SHALL BE CLASSIFIED IN ACCORDANCE WITH THEIR RATED CAPACITIES (AT 20 PSI 1.4 BAR RESIDUAL PRESSURE OR OTHER DESIGNATED VALUE) AS FOLLOWS; CLASS AA -RATED CAPACITY OF 1.500 GPM OR (TREATER (5,680 L/NIIN), CLASS A RATED CAPACITY OF 1,000-1.,499 GPM (3,785-5,675 L/MTN), CLASS B-RATED CAPACITY OF 500-999 GPM (1,900-3780 L/MIN), CLASS C-RATED CAPACITY OF LESS THAN 500 GPM (1,900LJMIN). ALL BARRELS ARE TO BE CHROME YELLOW, WITH TOPS AND NOZZLE GREEN. COUNTY OF RIVERSIDE FIRE DEPARTMENT APPROVED BY RIVERSIDE COUNTY FIRE DEPARTMENT imothy Williams APPROVED BY DATE Rancho Water RANCHO CALIFORNIA WATER DISTRICT 42135 WINCHESTER ROAD TEMECULA, CA 92590 PHONE (951) 296-6900 FAX (951) 296-6863 9.29.21 RIVERSIDE COUNTY HEALTH DEPARTMENT NIA APPROVED BY DATE RANCHO CALIFORNIA WATER DISTRICT APPROVED FOR CONSTRUCTION LENGINEERING MANA R DATE OPERATIONS & MAINTENANCE DATE ENGINEERING DATE C RAC S 1NSPECTIONS (-- ATE �L POTABLE WATER CONSTRUCTION NOTES a - CONSTRUCT 8" O C900 DR-14 PVC PIPELINE (DESIGN PRESSURE=200 lbs/in2) PER RCWD STD DWG RW-22 Q- INSTALL I" AIR VACUUM & AIR RF,LFASE ASSEMBLY PER RCWD STD DWG NO(S). RW-1 A & RW-9 ®- CONSTRUCT 6" RESIDENTIAL FIRE HYDRANT ASSEMBLY PER RCWD STD DWG NO(S), RW-IA, RW-8 & RW-26 ® - INSTALL 1" COPPER WATER SERVICE ASSEMBLY PER RCWD STD DWG NO(S). RW-IA, RW-13 & RW-16 Q- CONSTRUCT 6" RESIDENTIAL FIRE HYDRANT ASSEMBLY PER RCWD STD DWG NO(S), RW-1 A & RW-24A NOT COUNTY MAINTAINED ROAD PM25962 IP210166 (REFERENCE: BGR160122) POTABLE RCWD 2860 PRESSURE ZONE COUNTY OF RIVERSIDE WATER IMPROVEMENT PLAN PARCEL MAP 25962 AND 25963 CORTE FUENTES TITLE SHEET AND NOTES SHEET 1 OF 2 SHEETS RCWD H1705P COUNTY FELE # 895 - XX 2560 2550 2540 2530 64 2520 � � Q r4 Z 3 + 00 P� M M E I QNP SURE 200 S H _ Q tA N 77+7 1 1 C I NT R IN 8" W. T 16+ OA if 110' / RESI RAIN ALL Toll FFS 254 .5 O c 16 5. 0 U a / 25 7.3 + O0 _. 16 3. 0 ST LL Utn 0 c tn '� 2547.1 ✓ .k eq N /11 j�� � O O O - - I - I - I - - - + ¢ + + 00 °° EXISTING - ; O - r- N - w :U N N000, . . ........... i - I+ -e,000,- i S- 050 1 S= 6 20.00 LF s` V., - -,%-, - S= 053 0 p" -+0. 110 T ¢� a w w O M w T a N t p n O o C? � 0 o U o U O w rn N FQ O . ¢ N N O N Vt++ N '!i N I T - + vNi x N + -- �r SCALE: H: 1= 401 V: 1" = 4' I i 10+00 - 0.0 LF 8" VC 90. 0 F 8' PV 29 .00 F " P C 90 D -14 (R 175 00 F 8' P C 90 D 14 C 17+nn - 11+00 - 12+Q0 13+00 14+00 - 15+00 16+00 tA N � h 4 � � v (� VC 10 20 40 60 80 1.00 SCALE: 1 "=40' 1 i 1 1 �y rr 4 EXISTING F.H. PER SR-169 uJ 679+55.00 HACIENDA DR.= r C S 9+92.00 CORTE FUEhiTF.S- ko Z g 679+45.00 HACIENDA DR. l 10+00.00 CORTE F ENTES EXISTING 8"xg"x81 TEE AND W �J 8" RSGV (FxRJ)(N) j I 1 o N 2,138,083.50 U b1 E 6,226,911.52 r -w 4 0. 5a I �T bdMoL 1 lvort�E�� I I , DESCRIPTION PE= 2555 �` PARCEL 3 ~Y PARCEL MAP 25962 PM 180/91-92 APN: 932-350-013 11+10.00 INSTAL] 6" F.H. PER RW-8 1 BLUE REFLECT PAVEMENT MAID 2527.00 FL X EXISTING 18" CMP 1 10+25.00 INSTALL 1" AIR 2 11+80.00 INS I VACUUM & AIR RELEASE V COPPER W TE ASSEMBLY PER RW-9 SERVICE ASS Ml - -- -- -- t PER RW-13 25' 03" E 1 { 11 )110+20.00 REMOVE EXISTING THRUST BLOCK & CAP. i CONNECT NEW 8" 0 C900 DR-l4 PVC TO 1 EXISTING 8"0 CML&C PE= 2578 \ PARCEL l PARCEL MAP 25962 PM 180/91-92 APN: 932- 50-012 �r r , 1 it�-�------- _----- I CONSTRUCT 8" 0 C900 DR-14 PVI j 3 (DESIGN PRESSURE=2001bs/in2 ) I RCWD STD DWG RW-22 Y \ R/W r_� _13 _ 14 ------------- - 2520.51 F 1 it 11+60.00 INSTALL _ yr- 8 O CMP I" COPPER WATER 4 °` SERVICE ASSEMBLY co TES PER RW-13 3 PARCEL 4 a PARCEL MAP 25962 PM 180/91-92 PE- 2540 APN: 932-350-014 BENCH MARK: r EXISTING 8" CML&C Elevation= ELEVATION:1,933.00 NAD 83/NAVD 88 ' WATERLINE PER SR-169 BENCHMARK# RIVERSIDE COUNTY Z7150 SEE SHEET I BENCH MARK: LAKESHORE ENGINEERING 4�tO� ES SIp� RIVERSIDE COUNTY # Z 7150 OU D G 24 OAKHURST RD NAD 83/NAVD 88 EPOCH 2O07 tiw �� �l �� IRVINE, CA 92620 TENAJA ROAD NORTH OF SIERRA ELLENA C 59993 TEL: (949) 307-5410 3I4" IP W/RCFC TRI STA. PLUG FLUSH EXP.6-30-2022 E=6,243,666.88 PREPARED BY PE N0. 59993 N= 2,136,784.55 s�� �IVAy / l� o� � /L�!'� 5-20-2021 GPS EL: 1,933.00 OP CMASSOUD GHIAM DATE: STREET CENTERLINE DATA BEARING RADIUS LENGTH O N 07" 25' 03" E - 429.08' ® A = 30" 42' 39" 200' 107.20' N 230 17' 36" W - 29.45' 8 L = 25° 31' 48" 184.35' 82.14' 2560 2550 2540 POTABLE WATER CONSTRUCTION NOTES Q- CONSTRUCT 8" 0 C900 DR-14 PVC PIPELINE (DESIGN PRESSURE=200 lbs/in2) PER RCWD STD DWG RW-22 - INSTALL 1" AIR VACUUM & AIR RELEASE ASSEMBLY PER RCWD STD DWG NO(S). RW-1A & RW-9 CONSTRUCT 6" RESIDENTIAL FIRE HYDRANT ASSEMBLY PER RCWD STD DWG NO(S). RW-IA, RW-8 & RW-26 0) - INSTALL 1" COPPER WATER SERVICE ASSEMBLY PER RCWD STD DWG NO(S). RW-1A, RW-13 & RW-16 - CONSTRUCT 6" RESIDENTIAL FIRE HYDRANT ASSEMBLY PER RCWD STD DWG NO(S). RW-IA & RW-24A 2530 2520 1 161+47.00 INSTALL 4 1" COPP R WATER PARCEL 4 PARCEL MAP/•a S RVI 1i3 ASSEMBLY ' 25963,PM 180/93-94"+ RR ! 16+51.00 INSTALL 4 APN: 932-350-018 -•/ / C PPER WATER PE= 2625 SER ICE ASSEMBLY a PER W-13 PE= 2616 PARCEL 2 16+70.00 INSTALL 6 PARCEL MAP 25963 F.H. PER RW-24A PM 180/93-94 �s 1 BLUE REFLECTIVE PAVEMENT MARKER APN: 932-350-036 1 16+55.00 END N 2 13$ 733,05---_ _ 2 8" 0 WATERLINE 6,226,900.31 E " \ 16_+-53.00 INSTALL 1"AIR VACUUM & AIR RELEASE ASSEMBLY PER RW-9 16+49.00INSTALL 4 1" COPPER WATER VEWAY SERVICE ASSEMBLY PER RW-13 16+45.00 INSTALL I" COPPER WATER SERVICE ASSEMBL PARCEL 2 PER RW-13 PARCEL MAP 25962 PM 180/91-92 PE;-- 25 APN: 932-350-037 WATERLINE CONTROL DATA BEARING RADIUS TANGENT LENGTH O N 07° 25' 03" E - - 399.62' ® 0 = 300 42' 43" 210' 57.67' 112.56' O N 23° 17' 36" W - - 122.82' TOTAL 635.00' Rancho Water RANCHO CALIFORNIA WATER DISTRICT 42135 WINCHESTER ROAD TEMECULA, CA 92590 PHONE (951) 296-6900 FAX (951) 296-6863 R/W 60' 24' 18, 12' CL I 12' 4' 10, 4' 2:1 MAX 3" ASPHALT � I 2:1 MAX 6" COMPACTED AGG BASE COMPACTED NATIVE SOIL PM 25%2 r P 21 DI ro6 RANCHO CALIFORNIA WATER DISTRICT APPROVED FOR CONSTRUCTION Digitally signed by Jake Wiley Jake Wile Date: 2021.1 D.1$ 15:15:11 Y p Yt Digitally signed by Kevin Marcoux Kevin Marco U X _D7•oa Date: 2021 A 0.14 14:47:16-07100' ENGINEERING MANAGER DATE OPERATIONS & MAINTENANCE DATE Gregory M M. V I I � DnDDmgkalale lidrn l�l2ly-lcahvg1ge�n dMyowG. wGsreairlgll,e:o=�RMomCrYGoweo' flncho NMeI. CN=Lasvy Aintll ` IYN,,e Casey r n do- anL marry 10.20 o.so wO rsa]nlrewooi.,1.s oN.�.aM2RenuUu�zSM, ,�,o�RPF.0 e ENGINEERING DATE CONTRACTS AND INSPECTIONS DATE WATER LINE STREET SECTION (TYP) CORTE FUENTES APPROVED RIVERSIDE COUNTY FIRE DEPARTMENT OFFICE OF THE FIRE MARSHAL igllelly sgned by Timalhy N411amn Y' Timothy Williams' Ree>��'a :.i^gthisdo-M : 1 ❑ale 1 m, . , 31 nTW' FSS TIMOTHY WILLIAMS 09/29/2021 2:3433 PM The approval of plans and specifications does not permit the violation, deletion, omission or faulty installation of any requirements of Title 24 or any Local Ordinances. Construction shall remain accessible and exposed for inspection purposes until approved by the Fire Department, 18' POTABLE RCWD 2860 PRESSURE ZONE COUNTY OF RIVERSIDE SHEET WATER IMPROVEMENT PLAN PARCEL MAP 25962 AND 25963 CORTE FUENTES 2 PLAN AND PROFILE R/W STA. 10+20.00 TO STA 16+55.00 OF 2 SHEETS RCWD H1705P C,0UWY F t Lt#_ 695-XX a