Loading...
ecs042_070 ENVIRONMENTAL CONSTRAINT SHEET IN THE UNINCORPORATED TERRITORY OF THE COUNTY OF RIVERSIDE , STATE OF CALIFORNIA . SHEET 1 OF 1 SHEETS NO 29598 BEING A SUBDIVISION OF A PORTION OF LOT A OF LOT LINE ADJUSTMENT NO. 05545N88* 15'06"W, RECORDED 100.00, CK N66'44'53"W -0292452 OF OFFICIAL RECORDS OF RIVERSIDE COUNTY, JULY 13, 2016 AS INSTRUMENT NO. 2016 37.00' CALIFORNIA, TOGETHER WITH A PORTION OF THE EAST HALF OF THE NORTHEAST QUARTER OF THE (N89' 12'21 "W 670.84'R11 ) N89* 10' I C11 ,IN CD DRAINAGE NOTE , 6-7n N40' 14'53"W to 1� v /U.84' -�4- NORTHEAST QUARTER OF SECTION 9, TOWNSHIP 2 SOUTH, RANGE 4 WEST, AND ALL LYING WITHIN ---------- 17 120.00' 316.54 [354.30' ] =717 CN DRAINAGE EASEMENTS SHALL BE KEPT SECTIONS 9 AND 10, TOWNSHIP 2 SOUTH, RANGE 4 WEST, SAN BERNARDINO MERIDIAN. N55*29'53"W LLJ FREE OF BUILDINGS AND OBSTRUCTIONS. 17 62.00' (o � .9 16 107 uv 12J N60*59'53"W Michael Baker 16.00' INTERNATIONAL z POR NMI 714 SEC. 10 200 0 200 400 600 122 125 15 0 -1 N6,3'59'53"W T.2S. , R. 4 W. S.B.M. AUGUST 2015 -1 1,37.73' 1 121 14 80 81 82 - 0 1� 1� 523 56 �-A 120 102 79 83 • N89'59'49"W 2583.42' 11 1086.33' �3 -0'34'46 .9" CONVERGENCE SCALE IN FEET: 1"=200' 55 103 78 8 ANGLE AT POINT 150 A A\� 72 711 85 1A 1 70 2-r 0 > 0 104 >1 54 13 A 77 86 C, ) -0 117 DATA TABLE DATA TABLE 7 5,, 107 53 105 76 73 69 87 11 12 • 27 -- 68 RADIUS US LENGTH 35 75 00 Q-) BEARING/DELTA RADIUS LENGTH BEARING/DELTA �2 • 38 88 (o -- 28 Jo 34 0 g 1 �NOO*28'52"W 189.39' � 21 [01 '35' 18" 5000.00' 1,38.6 39 106 - 74 �o 67 89 u 2 X31 -23'52" 500.00' 274.00' � 22 <N04'03'02"E -- 37.05'> I I " 43 A . 4- -' o 10 29 5 66 90 SEE SHEET 13 3 �05*57'36" 1000.00' 104.02' 23 <N80'50'51"W 240.34'> \ 1- 0 • 2 1`3 44 91 4 N 3 6'5 2 6"E -- 297.34' � 24 <01 '44'39" 11 .5/'> 'o 30 49 42 / 65 -- 60.00'> III / 3 45 5 X18'08'22" 500.00' 158.30' � 25 <N82°35 30"W 61 41 92 178 64 6 �N18'44' 14"E 89.47' � 26 <03*21 ' 13" 320.00' 18.73'> \C1 �1\ , 110 4 4F) u 7 €24- 15'46" 300.00' 127.04' � 27 <N10*45'43"E -- 247.04'> 47 9 40 3 100 Q) J2 109 63 N -- 530.00' 120.81 '> 5 47 V 8 �1\143 00'00"E 211 .26' � 28 <13 0335" 39 94 0) < 62 9 5049'48" 1000.00' 276.29' z 29 <N020117'52" I X 6 11/0 � 1 W 37.86'> �p 46 4 99 38 10 JN31 '00'49"W 96.31 ' 30 <N82'54' 14"W 61 .85'> I'v/ > ' 11 �N59.03'09"E 33.00' � 31 <N74'49'43"W 61 .93'> ------- 49 0 161 95 45 37 J4 107 8 Ol 98 12 €N52'05'08"E 89.60' � 32 <N68 37'21"W 61 .93'> 50 60 44 8 106 36 107 13 €N26- 10'23"E 183.24' � 33 <N56'38'05"W 61 .91 '> 9 CN 59 58 51 N 14 €N32° 15'08"E 118.61 ' � 34 <N51 *51 ' 18"W -- 60.00'> 4,3 \11 105 97 j5 2 / // V-, 10 15 €N44'29'26"E 120. 17' � 35 <16*56'06" 270.00' 79.80'> \� 104 34 25 - 17'58"E -- -- Cj- -4b. - 7 j 52 24 16 �N58 122.73' � 36 <N55*04'48"E 32.64'> 36 42 103 26 96 - 37 4 102 53 22 LOT 3 17 �NOO*47'28"E 66.83' � 37 <N76'40'58"W 21 .00'> -- 1223 18 LN03*01 '40"W 151 . 15' 1 38 <01* 16'00" 967.00' 21 .38'> (6 J6 5 0, 32 54 55 56 57 0 L.L.A. N0. 05545 4 101 L 19 FN03 2016-0292452 0.R.*01 '40"W - 41 35 6 0 ^1 33. 19' 1 <N,30*56'51 "W 96.68'> �1�\ 31 83 % INST. NO, 20 [00'39'29" 1500.00' 17.2,3' ] 54 No 14 30 8 -9,9 27 25 82 72 jj 15 28 27 J( 291 2 40 98 7J Npl/ ig 52 16 THE ENVIRONMENTAL CONSTRAINT INFORMATION SHOWN ON THIS MAP /�o <<, 81 J / JI q/ SHEET IS FOR INFORMATIONAL PURPOSES DESCRIBING CONDITIONS AS OF 12 74 • '10 17 > 17 80 THE DATE' OF FILING, AND IS NOT INTENDED TO AFFECT RECORD TITLE 72 41 '96 // - (N89*52' 13"W 2600.08' R7) < 7J %/112 / 18 19 --7 29 95 33 24 28 INTEREST. THIS INFORMATION IS DERIVED FROM PUBLIC RECORDS OR 76 711 - ----- 1,3 20 (N89'52'52"E 2600.28' R6) REPORTS, AND DOES NOT IMPLY THE CORRECTNESS OR SUFFICIENCY OF 10 42 39 23 29 (N89'52'06"W 2600.88' R4) \> 28 4 .-ORDS OR REPORTS BY THE PREPARER OF THIS MAP SHEET. - THOSE RECORDS 84 4 \x 70 43 <S) 27 2 L 7-9= N89*52'08"E 2600.2l '- /\, 14 / 69 9 CIV\ \ --- - / 10 IN-- / 44 93 ENVIRONMENTAL CONSTRAINT NOTES / �/ 68 / 26 15 92 /* N88*21.'18"E. 328,17' 78 851 8 C), 45 Y 25 / \ / -91 30 CN /'\ 16 0 0) 2 61 / 90 85 84 - THE LAND DIVISION IS LOCATED IN THE "HAZARDOUS FIRE AREA OF 46 >< / 89 88 87 86 77 /�o / P) 3 24 / X / n 87 / �< 17 -4- / ov /<�) RIVERSIDE COUNTY AS SHOWN ON A MAP ON FILE WITH THE CLERK OF THE 0) j 82 66 18 86 47 23 BOARD OF SUPERVISORS. ANY BUILDING CONSTRUCTED ON LOTS CREATED BY 6 / 5 48 22 X// THIS LAND DIVISION SHALL COMPLY WITH THE SPECIAL CONSTRUCTION 4 81 ' \ 19 \ \c� .:ONTAINED IN RIVERSIDE COUNTY ORDINANCE 787.2. <) 3j PROVISION!- 91 5 80 64 /6j 491 20 60 X�16) 21 / - 76 5 \< 84 79 69 Qj 50 ----1 92 ) 68 4 V 62 C� ALL BUILDINGS SHALL BE CONSTRUCTED WITH CLASS "A" MATERIAL AS PER THE CALIFORNIA BUILDING CODE. 6 62 75 78 67 Q-�- 67 35 y 52 59 J i 53 70 60 11::) f YQ Q-) \ 74 PRIOR TO THE ISSUANCE OF A GRADING PERMIT, THE DEVELOPER SHALL YJ 77 94 92 9j 7 / \ 2 86 91 > 59 54 '5 56 63 66 71 PREPARE /�ND SUBMIT TO THE FIRE DEPARTMENT FOR APPROVAL A FIRE - 3 '94 76 57 58 /j I -----I r PROTECTION/VEGETATION MANAGEMENT THAT SHOULD INCLUDE BUT NOT 81- 65 73 75 58 64 LIMITED Tf THE FOLLOWING ITEMS: .<0 7 -- -\ �� 1 _ N� ° A) FUE-11- MODIFICATION TO REDUCE FIRE LOADING. 9 57 56 5r,..155 4 1 72 122 B) APPROPRIATE FIRE BREAKS ACCORDING TO FUEL LOAD, SLOPE AND 12i 97 98 TRACT P40 TERRAIN. 96 1 1 .1 . 1 98- 112 89 1 1 -�j 1 48 47 44 724 / --- , - --L-- ----LY 1 46 45 C) NON FLAMMABLE WALLS ALONG COMMON BOUNDARIES BETWEEN REAR 5j 125 / --- \\ 2 1 / /- 1 -- YARDS AND OPEN SPACE. 0 --1 1---, )VEARSST STREET I--," 1 1 43 D) EMERGENCY VEHICLE ACCESS INTO OPEN SPACE AREAS SHALL BE 20 \ / --/ ---r-1 ---L- \ / 22 / - PROVIDED AT INTERVALS NOT TO EXCEED 1500 . 62 23 124 25 42 CD 0) 16 17 18 7 --T E) A HOMEOWNER'S ASSOCIATION OR APPROPRIATE DISTRICT SHALL BE I J2 j RESPONSIBLE FOR MAINTENANCE OF ALL FIRE PROTECTION MEASURES 10 12 15 26 2 1 1 ---T 28 2,9 3 61 co 2 0 JI WITHIN OPEN SPACE AREAS. a- j-- 1341 35 r- CD -�4- 1 1 1 1 . 1I 41 y Li Lo 36 J/ 38 139 I4 CY) ANY HABITAT CONSERVATION ISSUE AFFECTING THE FIRE DEPARTMENT FUEL n r- CD Lf-- j- L O ✓ Lo - CD - ---L- _I �N MODIFICATION REQUIREMENT SHALL HAVE CONCURRENCE WITH THE 109 C) (D C) r- C14 (o (o (JD CD �o RESPONSIBLE WILDLIFE AND/OR OTHER CONSERVATION AGENCY. CN',I- -q- 4- CN CD C4 N THE REQUIRE[) WATER SYSTEM, INCLUDING FIRE HYDRANTS, SHALL BE Q /00 z bi-``'-`y' w tw-00 (D n INSTALLED AND ACCEPTED BY THE APPROPRIATE WATER AGENCY PRIOR TO ANY 101 n CN CN PIGEON PASS ROAD 4-q- -14- COMBUSTIBLE BUILDING MATERIALS PLACED ON AN INDIVIDUAL LOT. r r r 1\189°0-4'27"W 21 E ES FD 91, - --- PLEASE BE ADVISED THE PROPOSED PROJECT MAY NOT BE FEASIBLE SINCE THE EXISTING WATER MAINS WILL NOT MEET THE REQUIRED FIRE FLOW OF 0 W 2181 .60- 20 1321,15' 19 1000 GPM. N87*29'13"W 2642.31' 1321.16'21-16 DUE TO WATER LETTER RECEIVED FROM WATER DISTRICT NO FACILITIES EXIST AT THIS TIME. (R) TRAC I In Ff so' K 40%